Redback A 2078B Скачать руководство пользователя страница 9

Redback® A 4574

 Alert/Evac/Chime Tone Generator

www.redbackaudio.com.au

Redback® Proudly Made In Australia

9

Redback® A 4574

 Alert/Evac/Chime Tone Generator

12.0 Optional Remote Wall Plates

There are two optional remote wall plates which can be connected to the A 4574 for remote triggering of the Alert, Evac-
uation and Bell tones and for remotely cancelling any tones which may be active.

12.1 A 2078B Remote Plate

The A 2078B wall plate provides a remote means of trigger-
ing the Alert and Evacuation tones and the cancel function. 
Connection is made to the A 4574 via a minimum of 7 wires 
as shown in Fig 9. 
If standard Cat5 cable is used for the wiring, the plate can 
be located up to 30m away from the main unit. This can be 
increased to 100m away using heavier guage cable, which 
reduces the voltage drop across this distance and ensures the 
switch LEDs illuminate. 

The Alert/Evac/Cancel switches on the A 2078B wall plate are 
connected to the corresponding contacts on the rear of the 
A 4574. While the Alert and Evac LEDs on the wall plate are 
connected to the Alert 24V and Evac 24V outputs of the 
A 4574. The cancel LED is not connected. A mimimum of 
seven wires can be used if the ground connections of the 
Alert and Evac 24V outputs are linked and if the Alert/Evac 
and cancel switch grounds are linked together (see Fig 9).

   

Fig 

A 4574 REAR PANEL

L

R

Audio

 Out

24V 

DC IN 

www.redbackaudio.com.au

Manufactured in Australia 

By Altronic Distributors Pty. Ltd.

   1  2  3   4  5  6  7  8

 

DIP 

Switch 

Settings

DIP Switches

+

-

Volume

Bell

Voice

Over

Alert/

Evac

5

0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

6

0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1

7

0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1

8

0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

Delay

(Sec.)

O

FF

30

60

90

120

150

180

210

240

270

300

330

360

390

420

450

AUTO ALERT TO EVAC SWITCHOVER TIMER SETTINGS. 0 = OFF. 1 = ON.

SW

+_

24V 

DC In

Bell

Alert

Cancel

Evac

Contacts

N/O

GND

N/C

Switched

N/O

GND

N/C

N/O

GND

N/C

N/O

GND

N/C

24V Outputs

 

(Outputs limited to 120mA)

Evac

Alert

Bell

Interface

1 2

3

4 5

6

7 8

ON

4

Momentary operation 

of Alert & Evac contacts

Bell - Repeatedly plays until

Not Used

OFF

1
2

Bell - Plays Once after

SW

3

 

Continuous operation 

of Alert & Evac contacts

Not Used

Activation

Cancel Activated

Cancel

Switch

Evac

Switch

Alert

Switch

Alert

Lamp

Evac

Lamp

-   + -   +

Evac

Canc

el

Aler

t

A 2078B REMOTE WALL PLATE

Содержание A 2078B

Страница 1: ...instructions carefully from front to back prior to installation They include important setup instructions Failure to follow these instructions may prevent the unit from working as designed Distributed...

Страница 2: ...ion Switch This switch is used to cancel the Alert Evac or Bell tones Press for 2 seconds to activate 5 Micro SD Card This is used to store the MP3 audio files for the Alert Evac Bell and Message play...

Страница 3: ...Alert tone is activated The terminals provided can be used for Normal or Failsafe modes see section 8 0 for more details Bell 24V Out This is a 24V DC output which is activated when the Bell tone is...

Страница 4: ...s etc These contacts can be set to either continuous or momentary operation via dip switch 1 refer to secton 7 0 In continuous mode the alert tone will continue while the alert contact is triggered In...

Страница 5: ...same manner as the switched 24V out contacts i e connection between the N O contact and the GND contact will operate in NORMAL mode and connection between the N C contact and the GND will operate in...

Страница 6: ...in MP3 format they cannot be Wav files or AAC files NOTE only one MP3 file can be in each folder There is also a folder labelled LIBRARY which contains a host of sample MP3 files The Voice folder cont...

Страница 7: ...ed a PC or laptop equipped with a Micro SD card reader to do this If a Micro SD slot is not available then the Altronics D 0371A USB Memory Card Reader or similar would be suitable not supplied Step b...

Страница 8: ...ted and replaced by the MP3 file you want to play when you activate the Alert mode The MP3 file name is not important But it is important that there is only one MP3 file in the Alert folder Check the...

Страница 9: ...d to the Alert 24V and Evac 24V outputs of the A 4574 The cancel LED is not connected A mimimum of seven wires can be used if the ground connections of the Alert and Evac 24V outputs are linked and if...

Страница 10: ...he Alert Evac and Bell 24V outputs and the grounds of the Alert Evac Chime and cancel switches are linked together see Fig 10 Fig 10 13 0 Troubleshooting E v a c A l e r t C h i m e C a n c e l A 4574...

Страница 11: ...s Make sure the Alert Evac and Bell folders on the Micro SD card have MP3 files in them MP3 Audio files not playing Make sure they are in MP3 format Make sure Micro SD card inserted properly Check MP3...

Страница 12: ...ice OUTPUT LEVEL 0dBm DISTORTION 0 01 FREQ RESPONSE 140Hz 20kHz SIGNAL TO NOISE RATIO Alert Evac Chime 70dB typically OUTPUT CONNECTORS Audio Output RCA Stereo Socket Switched 24V DC Out Screw Termina...

Отзывы: