Redback A 2078B Скачать руководство пользователя страница 6

www.redbackaudio.com.au

Redback® Proudly Made In Australia

6

Redback® A 4574

 Alert/Evac/Chime Tone Generator

9.0 MP3 AUDIO FILES and ALERT and EVAC VOICE OVER MESSAGES

The supplied MIcro SD card houses all the MP3 audio files used for the output tones. These files are stored in six separate 
folders (see figure 4) and relate to the corresponding output. e.g. the Alert folder houses the MP3 file to be played when 
the Alert mode is triggered. 
These files can be any length and bit rate, but must be in MP3 format (they cannot be Wav files or AAC files).

(NOTE: only one MP3 file can be in each folder).

There is also a folder labelled “#LIBRARY# which contains a host of sample MP3 files.

The “Voice” folder contains the MP3 audio files played as the Alert and Evacuation messages. There are separate folders 
for both the Alert and Evac messages as shown in figure 4.

The messages have to be recordered in MP3 format using any readily available PC software or other means, and then 
transferred to these folders.

Fig 4.

10.0 Activating the Voice Over Message:

Voice over messages become active when an MP3 file is present in the relevant folder. 
If the voice over message is not required leave the folder empty.

Содержание A 2078B

Страница 1: ...instructions carefully from front to back prior to installation They include important setup instructions Failure to follow these instructions may prevent the unit from working as designed Distributed...

Страница 2: ...ion Switch This switch is used to cancel the Alert Evac or Bell tones Press for 2 seconds to activate 5 Micro SD Card This is used to store the MP3 audio files for the Alert Evac Bell and Message play...

Страница 3: ...Alert tone is activated The terminals provided can be used for Normal or Failsafe modes see section 8 0 for more details Bell 24V Out This is a 24V DC output which is activated when the Bell tone is...

Страница 4: ...s etc These contacts can be set to either continuous or momentary operation via dip switch 1 refer to secton 7 0 In continuous mode the alert tone will continue while the alert contact is triggered In...

Страница 5: ...same manner as the switched 24V out contacts i e connection between the N O contact and the GND contact will operate in NORMAL mode and connection between the N C contact and the GND will operate in...

Страница 6: ...in MP3 format they cannot be Wav files or AAC files NOTE only one MP3 file can be in each folder There is also a folder labelled LIBRARY which contains a host of sample MP3 files The Voice folder cont...

Страница 7: ...ed a PC or laptop equipped with a Micro SD card reader to do this If a Micro SD slot is not available then the Altronics D 0371A USB Memory Card Reader or similar would be suitable not supplied Step b...

Страница 8: ...ted and replaced by the MP3 file you want to play when you activate the Alert mode The MP3 file name is not important But it is important that there is only one MP3 file in the Alert folder Check the...

Страница 9: ...d to the Alert 24V and Evac 24V outputs of the A 4574 The cancel LED is not connected A mimimum of seven wires can be used if the ground connections of the Alert and Evac 24V outputs are linked and if...

Страница 10: ...he Alert Evac and Bell 24V outputs and the grounds of the Alert Evac Chime and cancel switches are linked together see Fig 10 Fig 10 13 0 Troubleshooting E v a c A l e r t C h i m e C a n c e l A 4574...

Страница 11: ...s Make sure the Alert Evac and Bell folders on the Micro SD card have MP3 files in them MP3 Audio files not playing Make sure they are in MP3 format Make sure Micro SD card inserted properly Check MP3...

Страница 12: ...ice OUTPUT LEVEL 0dBm DISTORTION 0 01 FREQ RESPONSE 140Hz 20kHz SIGNAL TO NOISE RATIO Alert Evac Chime 70dB typically OUTPUT CONNECTORS Audio Output RCA Stereo Socket Switched 24V DC Out Screw Termina...

Отзывы: