background image

8

OL28X

TM 

OPERATING INSTRUCTIONS cont.

www.redbacklasers.com.au

Distance Estimation with the OL28X

The OL28X can be used to estimate distances between the unit and the staff 

with the use of the “Stadia” lines whilst looking through the eyepiece.

By using the plumb bob hanging from under the locking screw of the tripod 

the exact position of the dumpy level can be marked on the ground.  Next 

set the staff up at the point that you want to estimate the distance to and 

look through the eyepiece.  Note the number of centimeters on the staff 

between the top and bottom stadia lines (short lines see page5), multiply 

this measurement by 100 and you have the distance between dumpy and 

staff in centimeters.  e.g. 5cm x 100 = 500cm which is 5m In other words 

whatever you read in centermetrs is the distance in meters.

5cm

5m

Содержание ol28x

Страница 1: ......

Страница 2: ...n 9 Calibration Self Check Technical Specifications 10 Care Maintenance Trouble Shooting 11 Warranty 12 2 Copyright CMI LasersTM RedBack lasersTM and Level1LasersTM All rights reserved CMI Industries...

Страница 3: ...and water The OL28X is simple to use Use the rough levelling bullseye vial to get the unit into self levelling range and the magnetically dampened compensator does the rest The OL28X features a rubber...

Страница 4: ...l Dumpy Unit 1 Lens Cover 2 Focus 3 Rubber Eypeice Sheild 4 Eyepiece Cross Hair Focus 5 Angle Estimator 6 Levelling Feet 7 Fine rotation Adjustment www redbacklasers com au Rough Levelling Vial OL28X...

Страница 5: ...Line View through OL28X Bottom Stadia Line Bubble Vial is roughly levelled using adjustment feet The bubble ONLY NEEDS TO BE SOMEWHERE IN THE CIRCLE for the dumpy level to self level Getting the bubb...

Страница 6: ...gh level of accuracy Next the front of the dumpy level needs to be pointed at the required target staff This is achieved with the help of the sight built into the top housing Rotate the complete level...

Страница 7: ...you can set the same height and so have a level site Vertical Alignment with the OL28X The OL28X can be used for vertical alignment such as fence post alignment This is simply acheived by placing the...

Страница 8: ...f the tripod the exact position of the dumpy level can be marked on the ground Next set the staff up at the point that you want to estimate the distance to and look through the eyepiece Note the numbe...

Страница 9: ...he OL28X can be used to estimate angles with the use of the angle finder scale Simply aim the dumpy level at the target point using the cross hair and zero off the angle finder scale by rotating the a...

Страница 10: ...calibration certified sticker with the date and name of technician is located on the laser level itself It is worth checking calibration from time to time particularly after any known knocks or drops...

Страница 11: ...e a cross hair through eyepiece A The cross hair needs focusing for your eye sight by rotating the adjustment ring on the eyepiece itself Q The Bubble Vial does not stay exactly central when I rotate...

Страница 12: ...ibration during the warranty period Note that this offer is invalid if the unit shows signs of accidental damage un authorised repair or abnormal use Also note that when returning the unit to us for f...