background image

WARNINGS & SAFETY INSTRUCTIONS

Save these instructions

 — this manual contains important safety 

instructions. Do not operate the system unless you have read and 
understood this manual. REDARC recommends that the Smart Start

®

 SBI 

referenced in this manual be installed by a suitably qualified person.

Disclaimer:

 REDARC accepts no liability for any injury, loss or property 

damage which may occur from the improper or unsafe installation or use of 
its products.

SAFETY MESSAGE CONVENTIONS

Safety messages in this manual contain a signal word that indicates the level 
of the hazard, as follows:

 WARNING

Indicates a potentially hazardous situation which 

could result in death or serious injury to the 
operator or to bystanders.

 CAUTION

Indicates a potentially hazardous situation which 

may 

result in moderate or minor injury to the operator 
or to bystanders.

NOTICE

Indicates a situation that 

may cause equipment 

damage.

 WARNING

RISK OF EXPLOSIVE GASES — Working in vicinity of a lead-acid 
battery is dangerous. Batteries generate explosive gases during 
normal operation. For this reason, it is of utmost importance that you 
follow the instructions each time you use the charger. 

 CAUTION

1. 

Only use the Battery Isolator for charging Standard Automotive Lead Acid, 
Calcium Content, Gel, AGM, SLI or Deep Cycle type batteries. 

2. 

Do NOT use the Battery Isolator to charge:

•  Dry-cell batteries that are commonly used with home appliances.
•  Batteries with voltage ratings other than 12 V (or 24 V for 24 V unit)
•  Non-rechargeable batteries
•  A frozen Battery. Thaw completely before attempting to charge.

Charging batteries under these circumstances may cause the battery to 
explode or rupture during charging and cause injury to persons, damage 
to the Battery Isolator and/or property.

3. 

NEVER smoke or allow a spark or flame in vicinity of battery or engine. This may 
cause the battery to explode.

4. 

Be extra cautious so as to reduce the risk of dropping a metal tool onto a 
vehicle battery. Doing so might cause the battery to spark or might short-circuit 
the battery or other electrical parts that may cause an explosion. 

5. 

Remove personal metal items such as rings, bracelets, necklaces, and watches 
when working with a lead-acid battery. A lead-acid battery can produce a 
short-circuit current high enough to weld a ring or the like to metal, causing a 
severe burn.

6.  A SPARK NEAR A BATTERY MAY CAUSE THE BATTERY TO EXPLODE. 

TO REDUCE THE RISK OF A SPARK NEAR A BATTERY WHEN 
CONNECTING THE BATTERY INSTALLED IN A VEHICLE TO THE 
ISOLATOR, ALWAYS DO THE FOLLOWING:

a. 

Position DC cords to reduce the risk of damage by the vehicle hood, door, or 
moving engine part.

b. 

Stay clear of fan blades, belts, pulleys and other parts that can cause injury to 
persons.

c. 

Check polarity of battery posts. The POSITIVE (POS / P / +) battery post usually 
has a larger diameter than the NEGATIVE (NEG / N / –) battery post however 
you should always check the label on the battery.

d. 

Determine which post of the battery is grounded (connected) to the chassis. If 
the negative post is grounded to the chassis (as in most vehicles), see (e). If the 
positive the post is grounded to the chassis see (f).

e. 

For a negative-grounded vehicle, connect the POSITIVE (Red) terminals from the 
Battery Isolator to the POSITIVE (POS, P, +) ungrounded post of each battery. 
Connect the NEGATIVE (Black) lead to a metal part of the frame or the vehicle 
chassis, away from the battery. Do not connect the connect to the carburettor 
or fuel lines. 

f. 

For positive-grounded vehicles, connect the NEGATIVE (Black) lead from the 
Battery Isolator to the NEGATIVE (NEG / N / –) ungrounded post of the battery. 
Connect the POSITIVE (RED) terminals to the POSITIVE (POS / P / +) post of 
each battery. Do not connect the connect to the carburettor, fuel lines, or sheet-
metal body parts. Only the start battery should be connected to the chassis.

PERSONAL SAFETY PRECAUTIONS:  

To assist with the safe working with batteries:

1. 

Consider having someone close by to come to your aid when you are working 
with the Battery.

2. 

Have plenty of fresh water and soap nearby in case battery acid contacts skin, 
clothing, or eyes.

3. 

Wear complete eye protection and clothing protection. Avoid touching eyes 
while working near a battery. 

4. 

If battery acid contacts your skin or clothing, remove the affected clothing and 
wash the affected area of your skin immediately with soap and water. If battery 
acid enters your eye, immediately flood the eye with running cold water for at 
least 10 minutes and seek medical assistance immediately.

NOTICE

1. 

It is recommended that Start and Auxiliary Batteries be of similar chemical 
characteristics when charging via the Smart Start

®

 SBI.

2. 

The Smart Start

®

 SBI will achieve best results when proper battery maintenance 

is regularly performed. This includes but is not limited to checking water and 
specific gravity levels of the battery. Refer to the battery manufacturers manual 
for more details.

3. 

Fuses or Circuit breakers of appropriate rating must be installed to protect the 
vehicle system. Refer to the installation instructions for specific instructions on 
where to install Fuses or Circuit breakers. Refer to the cable sizing table found 
in this manual for appropriate Fuse or Circuit Breaker ratings.

4. 

Fuses must be installed as close as possible to the battery.

5.  IMPORTANT!

 Do NOT make any connections to the control terminals on the 

front of the unit (100 A models) or the top of the unit (200 A models). Connecting 
to the control terminals on the front of the SBI may cause damage to the unit 
and/or equipment connected to it. Connecting to the control terminals will void 
the warranty of the unit.

Do NOT connect

to the control 

terminals.

IMPORTANT! 

Ensure that connections are not accidentally bridged 

between terminals whilst tightening.

LIMITED WARRANTY

For full warranty terms and conditions, visit the Warranty page of the 
REDARC website at  

www.redarcelectronics.com/warranty

.

Refer to the contact details applicable to your region:

Australia, New Zealand & Europe

REDARC Electronics Pty Ltd, 23 Brodie Road (North),  
Lonsdale SA 5160, Australia.

Australia 

+61 8 8322 4848

New Zealand 

+64-9-222-1024

UK & Europe

  

+44 (0)20 3930 8109

North America

REDARC Corporation c/o Shallco, Inc.,  
308 Component Dr.
Smithfield, NC 27577, USA.

USA

 

+1 (704) 247-5150

Canada

 

+1 (604) 260-5512

Mexico

 

+52 (558) 526-2898

REDARC®, Smart Start® and THE POWER OF REDARC® are trademarks of Redarc 
Electronics Pty Ltd. Any use of such marks by REDARC is under license.  
Copyright © 2022 Redarc Electronics Pty Ltd. All rights reserved.

Содержание Smart Start SBI12

Страница 1: ...Smart Start SBI Smart Battery Isolator MODELS SBI12 SBI24 SBI212 SBI224 Dual Sensing ...

Страница 2: ...gative grounded vehicle connect the POSITIVE Red terminals from the Battery Isolator to the POSITIVE POS P ungrounded post of each battery Connect the NEGATIVE Black lead to a metal part of the frame or the vehicle chassis away from the battery Do not connect the connect to the carburettor or fuel lines f For positive grounded vehicles connect the NEGATIVE Black lead from the Battery Isolator to t...

Страница 3: ...fuse holders SBI12 SBI24 FK60 MIDI 60A Fuse Kit SBI212 SBI224 FK100 MEGA 100A Fuse Kit MIDI Fuse with Holder MEGA Fuse with Holder Fuse Assembly PRODUCT FUNCTION The Smart Start SBI is a microprocessor controlled Smart Battery Isolator and is designed specifically for use in multi battery applications as a solenoid priority system It protects the start battery from being excessively discharged by ...

Страница 4: ...und Connection Connect the Smart Start SBI ground terminal to chassis ground Remove any paint to ensure a good ground connection NOTE A good ground will ensure correct switching voltage 2 3 Select correct Circuit Breaker Fuse sizes and install at battery end of both positive cables 3 4 Connect the cables in the order shown as shown below 4 5 6 7 When using fuses make sure that the fuse makes a goo...

Страница 5: ...TIONS Why does the LED stay on after the vehicle is turned off The LED stays on indicating the Smart Start is on the batteries are linked until the voltage drops to 12 7V 25 4V for SBI24 This can take a few minutes to many hours depending on size state of charge of the batteries as well as load on the batteries To test this feature of the Smart Start with the engine turned off turn the headlights ...

Страница 6: ...0Amps 600Amps Standby Current 5mA Dimensions 75 70 80mm 3 2 8 3 2 90 95 100mm 3 5 3 7 3 9 Weight 200g 0 4lb 600g 1 3lb Warranty 2 years Standards CE C Tick AS NZS CISPR11 2004 D indicates Dual Sensing Models Voltage tolerance of 0 1V CONTACT Tech Support 1300 REDARC 1300 733 272 Australia 61 8 8322 4848 New Zealand 64 9 222 1024 UK Europe 44 0 20 3930 8109 USA 1 704 247 5150 Canada 1 604 260 5512 ...