PRODUCT FUNCTION
1.4
Turn On/Off Thresholds
Input
12V Vehicle Input 24V Vehicle Input
Solar
Input Trigger
Settings
Standard
Low
Voltage
Standard
Low
Voltage
N/A
Input
Open Circuit Low
voltage conditions
*
1
Turn ON
ABOVE
13.2V
12.0V
26.4V
24.0V
9.0V
Turn OFF
BELOW
12.7V
11.9V
25.4V
23.8V
9.0V
Input
Loaded Low
voltage
conditions*
2
Turn OFF instantly
BELOW
8.0V
16.0V
9.0V
Turn OFF after 20s
BELOW
9.0V
18.0V
N/A
Input
Over voltage
shutdown
Turn ON
BELOW
15.5V
32V
Turn OFF instantly
ABOVE
16.0V
32.5V
33.0V
Turn OFF after 20s
ABOVE
15.6V
32.1V
N/A
Output
Under voltage
shutdown *
1
Shutdown if Output Battery < 4V
There is a maximum 20 second delay before the charger will produce an output
any time a source is introduced into the system, this allows the unit to provide
optimum input sharing and effective battery isolation.
1.5
Error Codes
In the event of a fault with the unit installation, either battery or solar panel, ALL
the LEDs on the unit will flash to indicate the fault type. Flashing sequences are
described in the table below.
LED State
Description
1 flash (1 flash followed by 3.5 second off)
Internal Hardware Fault
2 flash (2 flash followed by 3.5 second off)
Unit under temp fault
3 flash (3 flash followed by 3.5 second off)
Unit over temp fault
4 flash (4 flash followed by 3.5 second off)
Output Battery Fault (Volts too high)
5 flash (5 flash followed by 3.5 second off)
I
nput under voltage (Battery)*
3
6 flash (6 flash followed by 3.5 second off)
Input over voltage (Battery or Solar panel)
*
3
If the unit is being supplied power from the vehicle and solar
simultaneously
and ONE of those sources is undervoltage, that specific source LED will flash 5
times. If the unit is being supplied power from the vehicle and solar with BOTH
sources under voltage, OR if the unit is being supplied power from one input
only and that input is undervoltage, ALL LED’s will flash 5 times.
*
1
Tested every 100 Seconds.
*
2
Constantly