GETTING STARTED - UNPACKING & SPECIFICATION
1.1
UNPACKING THE HOIST
The hoist will have been packed into a cardboard box or palletised (see weight details in specification)
Handling of all models of hoist & trolley will require lifting equipment and shouldn’t be moved by hand.
WHEN UNPACKING:
Ensure that both hoist and any ancillary equipment are recovered from the packaging. Small or delicate items may have been packed
separately. Check the contents against the supplier’s delivery note and advise the supplier immediately of any shortages.
Ensure that the hoist and ancillary equipment are undamaged. If the goods do not reach you in perfect condition, notify your supplier
immediately of any damage. Do not proceed with installation if the goods are damaged.
Ensure that a certificate of test and thorough examination together with a ‘CE’ certificate of conformity is included with the goods. Hand these
to the ‘responsible person’ for safe keeping. Check that the identifying mark (serial no), the safe working load (lifting capacity) and the ‘CE’
mark appear on the hoist.
SUPPLIER / MANUFACTURER
Red Rooster Lifting Ltd
Red Rooster Lifting Ltd
ADDRESS
Nauta House, The Meadows
Unit 26 Kelvin Way Trading Estate
Oldmeldrum, Aberdeenshire
Kelvin Way, West Bromwich
UK, AB51 0EZ
West Midlands, U.K. B70 7TW
TEL NO
01651 872101
0121 525 4162
MODEL
TCS-500-LF
SERIAL NO
SWL
500 KG
DATE OF PURCHASE
NAME PLATES
The name plate gives important information which must be retained. Hoist serial number, SWL, model, air pressure, air flow, hoist rating, chain
size, speed, year of manufacture and the manufacturers name and address.
ATEX - Explosive protection
In Europe and several parts of the world the use of non-electrical equipment in hazardous areas is covered by the ATEX 2014/34/EU Directive.
(Previously ATEX 94/9/EC) and BS EN ISO 80079-36+37
Standard hoists are suitable for use in ZONE 2 Gas areas certified as Ex Group II 3 G Ex h IIB T4 Gc
Standard hoists are suitable for use in ZONE 22 Dust areas certified as Ex Group II 3 D Ex h IIIB T135°C Dc
With extra protection can be used in ZONE 1 Gas areas certified as Ex Group II 2 G Ex h IIB T4 Gb
With extra protection can be used in ZONE 21 Dust areas certified as Ex Group II 2 D Ex h IIIB T135°C Db
Further protection allows the hoist to work in ZONE 1 Gas areas certified as Ex Group II 2 G Ex h IIC T4 Gb
Further protection allows the hoist to work in ZONE 21 Dust areas certified as Ex Group II 2 D Ex h IIIC T135°C Db
(not suitable for TCR Mini or TCS range, IIC or IIIC areas)
The following models can also be rated for mining (Ex Group I M2 Ex h I Mb) – TCR-500 to TCR-2000/2, TNC and TMH models. These
hoists can be used according to Equipment Group I Category M2 where equipment is intended to be de-energised in the event of an explosive
atmosphere.
The TCR-250, TCR-500/2, TCS-500 and TCS-980/2 models cannot be rated for mining.
CERTIFICATION
All new hoists are supplied with standard certification: Thorough Examination, EU Declaration of Conformity, which includes ATEX certificate
where required. Other documentation is available by agreement.
IN THE EVENT OF ANY PROBLEMS OR SHOULD YOU REQUIRE ASSISTANCE CONTACT THE SUPPLIER AS DETAILED ABOVE
QUOTING THE HOIST MODEL AND SERIAL NUMBER.
PACKAGING MATERIALS SHOULD BE RECYCLED OR DISPOSED OF ACCORDING TO LOCAL REGULATIONS.
DANGER
Содержание TC5-500-LF
Страница 1: ...LUBE FREE AIR HOIST USER MANUAL MODEL TCS 500 LF...
Страница 2: ......
Страница 35: ...D01 AH12 LF REV0 17 09 15 Brake Gears Suspension Body TCS 500 LF...
Страница 37: ...D01 AH12 LF REV0 17 09 15 Motor Valve Body TCS 500 LF Pendant...
Страница 39: ...D01 AH12 LF REV0 17 09 15 Motor Valve Body TCS 500 LF Cord...
Страница 41: ...D01 AH12 LF REV0 17 09 15 D01 P7 REV1 Pendant VRD 2R...
Страница 43: ...D01 AH12 LF REV0 17 09 15 D01 P2 REV1 Pendant VTP2M...
Страница 48: ......