MODEL TLA - TEMPERATURE LIMIT ALARM 

  

FM APPROVED, UL RECOGNIZED

  

2-LINE BY 4-DIGIT DISPLAY

  

EXCEED, OUTPUT, AND ALARM ANNUNCIATORS

  

FOUR BUTTON SILICONE RUBBER KEYPAD

  

THERMOCOUPLE OR RTD SENSOR INPUT

  

REMOTE RESET INPUT

  

MAIN LIMIT OUTPUT: 5A RELAY. SELECTABLE FOR HIGH OR 

LOW TRIP ACTIVATION

  

OPTIONAL ALARMS: 5A RELAY(S)

  

OPTIONAL NEMA 4X/IP65 SEALED FRONT BEZEL

  

PARAMETER SECURITY VIA PROGRAMMABLE LOCKOUTS

GENERAL DESCRIPTION

The TLA is a Factory Mutual approved temperature limit alarm, intended to 

provide an independent shutdown for thermal processes. The TLA accepts 

signals from a variety of temperature sensors (thermocouple or RTD elements), 

and its comprehensive programming allows it to meet a wide variety of 

application requirements.

Dual 4-digit displays allow viewing of the process temperature and limit 

setpoint simultaneously. Front panel indicators inform the operator of the 

process and output status. The main limit output and alarm outputs are field 

replaceable.

The limit output is selectable for high or low trip activation. If the process 

temperature goes above the limit setpoint for a high trip, or below the limit 

setpoint for a low trip, the limit relay will de-energize to initiate a process 

shutdown. The limit output cannot be reset until the process temperature returns 

to the proper operating range; manual reset is required (local or remote). Sensor 

failure will initiate a process shutdown.

Relay alarm(s) can be configured to activate according to a variety of actions 

(Absolute HI or LO, Deviation HI or LO, and Band IN or OUT) with adjustable 

hysteresis. A standby feature suppresses the alarm during power-up until the 

process stabilizes outside the alarm region.

The unit is constructed of a lightweight, high impact plastic case with a tinted 

front panel. The front panel meets NEMA 4X/IP65 specifications when properly 

installed. Multiple units can be stacked horizontally or vertically. Modern 

surface-mount technology, extensive testing, plus high immunity to noise 

interference makes the TLA extremely reliable in industrial environments.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the 

manual or on equipment must be observed to ensure personal safety and to 

prevent damage to either the instrument or equipment connected to it. If 

equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

Do not use the TLA to directly command motors, valves, or other actuators 

not equipped with safeguards. To do so can be potentially harmful to persons or 

equipment in the event of a fault to the unit.

-0.0

+0.6

-0.000

+0.024

-0.0

+0.6

-0.000

+0.024

(45     )

1.772

(45     )

1.772

(9.4)

0.37

4.17 (105.9)

1.95

1.95 (49.5)

(49.5)

EX OUT A1 A2

P

R

DIMENSIONS  In inches (mm)

FM

APPROVED

PROCESS CONTROL EQUIPMENT

Bulletin No.  TLA-B
Drawing No.  LP0553
Released 06/13

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

PANEL CUT-OUT

UL Recognized Component, 

File # E156876

CAUTION: Risk of Danger. 

Read complete instructions prior to 

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

Содержание TLA

Страница 1: ...to activate according to a variety of actions Absolute HI or LO Deviation HI or LO and Band IN or OUT with adjustable hysteresis A standby feature suppresses the alarm during power up until the process stabilizes outside the alarm region The unit is constructed of a lightweight high impact plastic case with a tinted front panel The front panel meets NEMA 4X IP65 specifications when properly instal...

Страница 2: ...nel latch Panel latch can be installed for vertical or horizontal instrument stacking One piece tinted plastic bezel Bezel assembly with circuit boards can be removed from the case to change the output board without removing the case from the panel or disconnecting wiring Unit meets NEMA 4X IP65 requirements for indoor use when properly installed Flame resistant Installation Category II Pollution ...

Страница 3: ...ded This is especially useful in applications where cable runs are long and portable two way radios are used in close proximity or if the installation is near a commercial radio transmitter Also Signal or Control cables within an enclosure should be routed as far away as possible from contactors control relays transformers and other noisy components 4 Long cable runs are more susceptible to EMI pi...

Страница 4: ... ventilation to ensure that the maximum operating temperature range is not exceeded Caution Disconnect power to the unit and to the output control circuits to eliminate the potential shock hazard when removing the bezel assembly Unit Removal Procedure To remove a unit from the panel first loosen the panel latch screws Insert flat blade screwdrivers between the latch and the case on either side of ...

Страница 5: ...ging applications two or more thermocouple probes may be connected to the TLA always use the same type Paralleling a single thermocouple to more than one TLA is not recommended Generally the red wire from the thermocouple is negative and connected to the TLA s common RTD When connecting the RTD be certain that the connections are clean and tight RTD sensors have a higher degree of accuracy and sta...

Страница 6: ...ode In this mode the process temperature is displayed in the main top display and the limit setpoint is displayed in the secondary bottom display When changes to the parameter configurations are needed the P button is pressed and the TLA will enter into the Parameter Mode PARAMETER CONFIGURATION BASIC STARTUP For basic start up it is important to verify or change Input Parameter Module 1 IN parame...

Страница 7: ...egree resolution If changed be sure to check all parameters FLtr Digital Input Filtering and Display Update Select the relative degree of input signal filtering and display update rate The filter is an adaptive digital filter that discriminates between measurement noise and actual process changes Therefore the influence on step response time is minimal If the signal is varying too greatly due to m...

Страница 8: ...n low acting with positive alarm value d LO deviation high acting with negative value d HI or band inside acting b IN is selected for the alarm action the indicator is OFF when the alarm output is ON See the Alarms section for complete details of each action If changed check alarm values The alarm values are either absolute values or relative to the limit setpoint value deviation and band alarms A...

Страница 9: ...r this flag perform calibration procedure as noted in the Calibration section Alternatively stepping through one of the calibration procedures clears the error flag but does NOT validate the calibration accuracy in any manner USER PARAMETER VALUE CHART TLA Number _____________ MNEMONIC PARAMETER USER SETTING Limit Setpoint Alarm 2 Value Password Alarm 1 Value Input Parameters MNEMONIC PARAMETER US...

Страница 10: ... ON OFF Energized High Trip Action Low Trip Action 5 0 Alarms Optional The alarm action figures describe the status of the alarm output and the front panel indicator for various over under temperature conditions The alarm output wave form is shown with the output in the automatic reset mode Select the alarm action with care in some configurations the front panel indicator LED might be OFF while th...

Страница 11: ...e The TLA display should equal the calibrated probe temperature Tolerance is 1ºC 4 Calibrate the cold junction temperature if out of tolerance RTD Ohms Reading Check 1 Connect RTD simulator with an accuracy of 0 1 ohm or better capable of operating with less than 150 µA to terminals 8 9 10 2 Configure Input Parameters Module 1 for linear ohms rLin input under tYPE 3 Compare the TLA read out with t...

Страница 12: ...rm up period before starting this procedure Do not use thermocouple wire for the millivolt or RTD ohms calibration This procedure may be aborted by disconnecting power to the TLA before exiting the configuration mode The existing calibration settings remain in affect Note After completing any of the calibration sequences the TLA defaults the input sensor type to thermocouple type J tc J Be sure to...

Страница 13: ...ISPLAY 1 Input is below range of TLA 2 Temperature below range of input probe 3 Defective or incorrect transmitter or probe 4 Excessive low temperature for probe 5 Loss of setup parameters OLOL OR ULUL IN LOWER DISPLAY 1 Signal input exceeds allowable range by 5 1 Check remote signal source 1 Check input parameters 2 Change to input sensor with a lower temperature range 3 Replace transmitter or pr...

Страница 14: ...t Board RBDLA210 AL1 LIMIT E B 0 7 8 4 MD1797 A2 A1 OUT EX P OUTPUT BOARD POWER CPU BOARD SUPPLY BOARD OUTPUT BOARD CONNECTOR BEZEL DISPLAY BOARD ASSEMBLY BEZEL BOARD LATCH DISPLAY BOARD CONNECTOR 9 0 Terminal Configurations 50 60 HZ 8VA 14 12 85 250 VAC AC 1 A2 N O 13 COMM COMM A1 N O LIMIT RELAY ALARM RELAYS 4 N O 5 AC 11 2 3 6 REMOTE RESET 9 TC 10 RTD 8 7 COMM 50 60 HZ 9VA AC 24V 10 DC 18 36V 7...

Страница 15: ...15 This page intentionally left blank ...

Страница 16: ...h Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those...

Отзывы: