The  meter  has  a  switch,  which  must  be  checked  and/or  changed  prior  to 

applying power. To access the switch, remove the meter base from the case by 

firmly squeezing and pulling back on the side rear finger tabs. This should lower 

the latch below the case slot (which is located just in front of the finger tabs). It 

is recommended to release the latch on one side, then start the other side latch.

Power Selection Switch

Caution: Insure  the  AC power  selection  switch  is  set  for  the 

proper voltage before powering-up the meter. The meter is shipped 

from the factory in the 230 VAC position.

Set-Up DIP Switches

A DIP switch is located inside the meter. It is used for the selection of decimal 

points  and  backlight  annunciator.  Selecting  the  “ON”  position  enables  the 

function.

4

2.0 s

eTTing

 

The

 s

wiTChes

1.0 i

nsTalling

 

The

 m

eTer

Installation 

The PAX meets NEMA 4X/IP65 requirements when properly installed. The 

unit is intended to be mounted into an enclosed panel. Prepare the panel cutout 

to the dimensions shown. Remove the panel latch from the unit. Slide the panel 

gasket over the rear of the unit to the back 

of the bezel. The unit should be installed 

fully  assembled.  Insert  the  unit 

into the panel cutout. 

While holding the unit in place, push the panel latch over the rear of the unit 

so that the tabs of the panel latch engage in the slots on the case. The panel latch 

should be engaged in the farthest forward slot possible. To achieve a proper seal, 

tighten  the  latch  screws  evenly  until  the  unit  is  snug  in  the  panel  (Torque  to 

approximately 7 in-lbs [79N-cm]). Do not over-tighten the screws.

Installation Environment

The unit should be installed in a location that does not exceed the maximum 

operating temperature and provides good air circulation. Placing the unit near 

devices that generate excessive heat should be avoided.

The bezel should be cleaned only with a soft cloth and neutral soap product. 

Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the 

aging process of the bezel.

-.00

(92    )

-.0

+.8

3.62

+.03

(45    )

1.77

-.0

+.5

-.00

+.02

PANEL CUT-OUT

LATCHING

TABS

PANEL

LATCH

PANEL

MOUNTING

SCREWS

LATCHING

SLOTS

PANEL

GASKET

BEZEL

PANEL

Backlight Annunciator for Units Label

4

Decimal Point 3 (0.000)

3

Decimal Point 2 (00.00)

2

Decimal Point 1 (000.0)

1

FUNCTION

SWITCH

Main

Circuit

Board

SET-UP

DIP

SWITCHES

POWER SELECTION

SWITCH

230

11

5

REAR TERMINALS

FRONT DISPLAY

3

4

1

2

ON

Содержание PAX Lite PAXLHV

Страница 1: ... is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired DEFINITION OF TERMS INSTALLATION CATEGORY overvoltage category I Signal level special equipment or parts of equipment telecommunication electronic etc with smaller transient overvoltages than Installation Category overvoltage category II INSTALLATION CATEGORY overvoltage category II Loca...

Страница 2: ...ut Meter Part Numbers Accessories Part Number PAXLBK30 Units Label Kit Accessory PAXLBK Accessories TYPE PART NUMBERS DESCRIPTION MODEL NO Ordering Information 2 General Meter Specifications 3 Accessories 3 Installing the Meter 4 Setting the Switches 4 Wiring the Meter 5 ...

Страница 3: ...9 20041018 Issued by Underwriters Laboratories Inc IEC 61010 1 EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 IP65 Enclosure rating Face only IEC 529 ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326 Electrical Equipment for Measurement Control and Laboratory use Notes 1 Criterion A Normal operation within specified limits 2...

Страница 4: ...to the back of the bezel The unit should be installed fully assembled Insert the unit into the panel cutout While holding the unit in place push the panel latch over the rear of the unit so that the tabs of the panel latch engage in the slots on the case The panel latch should be engaged in the farthest forward slot possible To achieve a proper seal tighten the latch screws evenly until the unit i...

Страница 5: ... properly connected to protective earth 2 Use shielded screened cables for all Signal and Control inputs The shield screen pigtail connection should be made as short as possible The connection point for the shield depends somewhat upon the application Listed below are the recommended methods of connecting the shield in order of their effectiveness a Connect the shield only at the panel where the m...

Страница 6: ...6 This page intentionally left blank ...

Страница 7: ...7 This page intentionally left blank ...

Страница 8: ...uyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those ex...

Отзывы: