background image

Industry Canada 

 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) 
this  device  may  not  cause  interference,  and  (2)  this  device  must  accept  any  interference,  including  interference  that  may  cau se 
undesired operation of the device. 
 
This  radio  transmitters  BT-5630v2  /  BT-5830v2  (IC:  2991A-BT5X30V2)

 

and  BT-5730v2  have  been  approved  by  Industry  Canada  to 

operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna  
type  indicated.  Antenna  types  not  included  in  this  list,  having  a  gain  greater  than  the  maximum  gain  indicated  for  that  type,  are 
strictly prohibited for use with this device. 
 
A portable duct-type antenna with 3dBi gain and 50 ohm impedance is the approved antenna type.

 

 

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain 
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and  its gain 
should  be  so  chosen  that  the  equivalent  isotropically  radiated  power  (e.i.r.p.)  is  not  more  than  that  necessary  for  successful 
communication. 
 

To  comply  with  Industry  Canada  RF  exposure  limits  for  general  population/uncontrolled  exposure,  the  antenna(s)  used  for  this 
transmitter  must  be  installed  to  provide  a  separation  distance  of  at  least  20  cm  from  all  persons  and  must  not  be  collocated  or 
operating in conjunction with any other antenna or transmitter. 

 
Le présent appareil est conforme aux CNR  d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est 
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 
 
Conformément  à  la  réglementation  d'Industrie  Canada,  le  présent  émetteur  radio  peut  fonctionner  avec  une  antenne  d'un  type  et  
d'un  gain  maximal  (ou  inférieur)  approuvé  pour  l'émetteur  par  Industrie  Canada.  Dans  le  but  de  réduire  les  risques  de  brouillage 
radioélectrique  à  l'intention  des  autres  utilisateurs,  il  faut  choisir  le  type  d'antenne  et  son  gain  de  sorte  que  la  puissanc e  isotrope 
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. 
 
Le présent émetteur radio (identifier le dispositif par son numéro de certification ou son numéro de modèle s'il fait partie  du matériel 
de catégorie I) a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés ci-dessous et ayant un gain 
admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou don t le 
gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.

 

 

Содержание IndustrialPro BT-6401

Страница 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Страница 2: ...IndustrialPro and MobilityPro Gateway Wireless Modems User s Guide Version 1 15 August 15 2014...

Страница 3: ...consequential indirect or incidental special damages or loss of profits or data even if they were foreseeable and Red Lion has been informed of their potential occurrence arising out of or in connect...

Страница 4: ...measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the recei...

Страница 5: ...r must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter Le pr sent appareil...

Страница 6: ...s These devices are intended for use in Class I Division 2 Hazardous Locations industrial control applications The enclosure shall be suitable for the location AVERTISSEMENTS POUR INSTALLATION ET ENDR...

Страница 7: ...2 Updated to cover BT 57xx LTE models 1 13 February 15 2012 Updated to cover BT 5x30 Wi Fi models 1 10 September 27 2010 Update event and store and forward sections Update environmental specifications...

Страница 8: ...g Features 35 6 1 Port forwarding 35 6 2 DMZ 36 6 3 IP pass through 37 6 4 Dynamic IP registration 38 6 5 IP Security IPSEC 38 6 6 Access Control List ACL 39 6 7 Password protection 39 7 Serial IP 41...

Страница 9: ...1 12 Appendixes 53 12 1 BlueVue Device Manager Troubleshooting 53 12 2 Activation Troubleshooting 57 12 3 Troubleshooting 60 12 4 Firmware Upgrades 63 12 5 Sending AT Commands 65 12 6 Dial Up Networki...

Страница 10: ...rd protection 39 Figure 16 Serial IP 41 Figure 17 GPS configuration screen 42 Figure 18 Modem with good signal strength 57 Figure 19 Phone number being displayed on the Modem Diagnostic screen after a...

Страница 11: ...GSM EDGE GSM HSPA LTE MobilityPro Gateway Standalone GPS BT 5600v2 BT 5800v2 BT 5700v2 Standalone GPS with Wi Fi BT 5630v2 BT 5830v2 BT 5730v2 IndustrialPro Gateway 4 pin power connector BT 6600 BT 6...

Страница 12: ...vate LAN IP address to the attached device The modem then routes packets back and forth between its WAN and LAN connections and in turn allows the locally attached device to communicate with computers...

Страница 13: ...IP The modem can provide a reliable means of communication with serial only legacy devices It can encapsulate data coming from the serial port into a TCP or UDP packet and send it to a remote server...

Страница 14: ...porting Partner apps The modem can host partner applications used for example to report cellular traffic usage vehicle diagnostics alarms 1 3 Specifications 1 3 1 General specifications Table 2 Genera...

Страница 15: ...000 series Operating Temp 40 to 85 C 40 to 185 F Shock Vibration IEC 60068 2 1 2 6 27 30 DNV 2 4 3 7 8 9 MIL STD 810F 202G Humidity 5 to 95 non condensing Certification Hazardous Locations Class I Div...

Страница 16: ...1 3 3 Mechanical specifications BT 6000...

Страница 17: ......

Страница 18: ...pins are described as follows Table 3 4 pin Molex connector BT 5000v2 O3 IGN GND POS Power connector facing modem Pin Name Description 1 GND Ground 2 POS Power supply input 8 to 30 VDC 3 IGN Ignition...

Страница 19: ...le 6 DC 2 5mm Barrel adapter BT 6000 Power connector facing left side Pin Name Description Sleeve GND Ground Tip PWR Power supply input 8 to 30 VDC WARNING DC 2 5mm Barrel Adapter shall not be used in...

Страница 20: ...r reversed polarity and power surges over 33 volts The modems are equipped with an internal 3 Amp fuse When using the 4 pin Molex connector power accessory cable supplied by BlueTree Wireless an extra...

Страница 21: ...power connector BT 6x00 BT 6600 BT 6700 BT 6800 Screw block power connector BT 6x01 BT 6401 BT 6601 BT 6701 BT 6801 Screw block power connector PoE power input BT 6x01EB BT 6401EB BT 6601EB BT 6701EB...

Страница 22: ...tor BT 6x00 BT 6600 BT 6800 Screw block power connector BT 6x01 BT 6401 BT 6601 BT 6801 Screw block power connector PoE power input BT 6x01EB BT 6401EB BT 6601EB BT 6801EB Ethernet Switch BT 6x21 BT 6...

Страница 23: ...y with host GPS BT 5x00v2 OFF No position fix available ON Position fix available 1 3 8 Data Interface Specifications Serial Ethernet USB 1 3 8 1 Ethernet Port The modem s 10 100Mbps Ethernet port is...

Страница 24: ...tory restore Press and hold between 3 and 10 seconds RS232 LED flashes quickly Overwrites user configuration with the default factory settings FW upgrade Press and hold between 10 and 15 seconds WAN L...

Страница 25: ...ng BVDM refer to the BlueVue Device Manager User s Guide It can be accessed from within BVDM itself by clicking the Help button or downloaded separately at www redlion net BVDM is a Graphical User Int...

Страница 26: ...n click OK 2 1 2 Using an Ethernet or USB cable 3 Select Modem IP 4 Enter the appropriate modem IP then click OK By default the DHCP assigned IPs will be 192 168 0 1 for Ethernet and 192 168 111 1 for...

Отзывы: