background image

LEDS

STS – STATUS LED

The Status LED is a dual color LED that provides information regarding the 

state of the module. This includes indication of the various stages of the start-up 
routine (power-up), as well as any errors that may occur.

Startup Routine

Error States

ALM – ALARM LED

The Alarm LED indicates the presence of a fault condition.

FIRMWARE UPGRADE

The module’s firmware is stored in flash memory so that software/hardware 

conflicts are avoided, and so that software features may be added in the future.

During a download, Crimson compares its own library of firmware files with 

those stored in the Master module. If they do not match, Crimson will download 
the necessary files. The Master then checks to make sure that the I/O modules 
contain the same firmware. If they contain a different revision, the Master will 
automatically copy those files into the module's flash memory. During this 
process, the module LEDs will flash rapidly, starting with the top row, and 
progressing through the remaining rows until the process is complete.

CONFIGURATION

Programming is done via Crimson, a Windows

®

 compatible configuration 

interface. Please see the Crimson manual for more information.

Solid Red

Module not controlling, and not communicating.

Green/Pulsing Red

Module is controlling properly, but has lost 
communication with the Master.

ORDERING INFORMATION

Note: Certain modules are not suitable for use in Hazardous locations. Check each module’s specifications prior to installation.

1

 Visit www.redlion.net for a complete list of PID modules, data acquisition modules, communications drivers and cables.

Free at www.redlion.net

Programming Cable for CS, G3, & Paradigm Series 

Crimson Programming Software

2

Communications Cables

1

Crimson Programming Software, Manual, and Download Cable

Rail Stops (Qty 2)

Replacement Base

Replacement Termination Plug

CBL

Communication Cables 

(10 feet)

Software

Accessories

CBLPROG0 

SFCRM

CBLxxxxx

SFCRK

RSRSTP00

CSBASE00

CSTERM00

4-Channel Analog Output Module

Modular Controller Master, Multi Comms ports and Ethernet

CSOUT

1

CSMSTR

Analog Output Module

Master Module

CSOUT400

CSMSTRGT

CSMSTRSX

DESCRIPTION

MODEL NO.

TYPE

PART NUMBER

Module performing normally.

Green

Module switching to configuration.

Steady Red

Module is currently running the boot loader and/or 
being flash upgraded by Crimson. This occurs for 
four seconds during a power up.

Rapidly Flashing Red

CSMSTRV2

Modular Controller Master with multiple protocol converter, data 
logger, web server with Virtual HMI up to VGA (640 x 480) size 
and expansion slot with increased SDRAM

Modular Controller Master with multiple protocol converter, data 
logger, web server with Virtual HMI up to QVGA (320 x 240) size 
and expansion slot.

LIMITED WARRANTY

The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from 
the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s 
liability under this limited warranty shall extend only to the repair or replacement of a defective product, at The Company’s option. The 
Company disclaims all liability for any affirmation, promise or representation with respect to the products.

The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses 
arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal 
injuries, deaths, property damage, lost profits, and other matters which Buyer, its employees, or sub-contractors are or may be to any 
extent liable, including without limitation penalties imposed by the Consumer Product Safety Act (P.L. 92-573) and liability imposed 
upon any person pursuant to the Magnuson-Moss Warranty Act (P.L. 93-637), as now in effect or as amended hereafter.

No warranties expressed or implied are created with respect to The Company’s products except those expressly contained herein. The 
Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations.

Red Lion Controls
Headquarters
20 Willow Springs Circle
York PA 17406
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839

Red Lion Controls

China

Unit 101, XinAn Plaza

Building 13, No.99 Tianzhou Road

ShangHai, P.R. China 200223

Tel +86 21 6113-3688

Fax +86 21 6113-3683

Red Lion Controls

Europe

Printerweg 10

NL - 3821 AD Amersfoort

Tel +31 (0) 334 723 225

Fax +31 (0) 334 893 793

Red Lion Controls

India

54, Vishvas Tenement

GST Road, New Ranip,

Ahmedabad-382480 Gujarat, India

Tel +91 987 954 0503

Fax +91 79 275 31 350

Отзывы: