DISPLAYS INVERSE OF INPUT RATE

!

2 MODELS: 9999 & 999-59

!

0.56" (14.2 mm) HIGH LED DISPLAY (APLPT)

!

EASY SELECTION OF DISPLAY & SCALE MULTIPLIER VALUES

!

PROGRAMMABLE INPUT CIRCUIT. ACCEPTS OUTPUTS FROM

A WIDE VARIETY OF SENSORS

!

DECIMAL MODE SELECT (9999 Model Only)

!

POWER-UP SELF-TEST

!

0.02% ACCURACY

!

INPUT RATE 0.05 CPS TO 10,000 CPS

!

8 PULSE MOVING WINDOW AVERAGE BELOW 3 CPS

(Selectable)

!

NEMA 4/IP65 SEALED FRONT METAL BEZEL

DESCRIPTION

The Apollo Process Time Indicator (Model APLPT) and Module (Model

PBLPT) displays a value representing the time between a beginning and end
point of a process, such as a conveyor oven.

The unit’s display will update inversely in relation to the input signal

frequency. As input frequency increases (representing speed), the
APLPT/PBLPT time display decreases, indicating a reduction in the duration of
process time. For example, the baking time through an oven is inversely
proportional to the conveyor speed.

The APLPT/PBLPT is available in two versions: The Decimal Point version,

APLPT4/PBLPT4, that has 4 digits with different modes that provide for
decimal points; and the chronometer display version, APLPT5/PBLPT5, which
will show as its maximum value, 999-59.

The units have a feature called “

moving window average

”. This allows one

time disturbances, or irregularly spaced items to be averaged over eight input
pulses, thus keeping display fluctuations to a minimum while still updating the
display on every input pulse. This feature can be enabled or disabled by a side
panel DIP switch.

The units can accommodate magnetic pickups, logic sensors, and NPN open

collector sensors, as well as switch contact closure sensors.

These units have a self-test feature, which checks all the micro-processor and

display driver circuitry at power-up (if enabled). This self-test can also be used
to test display and scale multiplier select DIP switches to make certain all
switches are functioning properly.

Power and input connections are made via a removable terminal strip, located

at the rear of the unit. This strip can accept one #14 AWG wire. DIP switches at
the side of the unit are used to program the input configuration and to set the
scale multiplier value.

The Model APLPT has a sealed metal die-cast bezel which meets NEMA

4/IP65 specifications for wash-down and/or dust, when properly installed. Two
mounting clips are provided for easy installation. The Model APLPT has a 0.56"
high LED display, which is readable to 23 feet (7 M).

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

MODELS APLPT - APOLLO PROCESS TIME INDICATOR AND
PBLPT - 4/5 DIGIT MODULE FOR USE WITH THE LARGE DIGIT DISPLAY (LDD)

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) formounting clip installation is 2.1" (53.4) H x 5.5" (140) W.

CAUTION: Risk of Danger.

Read complete instructions prior to

installation and operation of the unit.

CAUTION: 

Risk of electric shock.

Bulletin No.  APLPT-J
Drawing No.  LP0141
Released  9/05

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

PANEL CUT-OUT

Содержание APLPT

Страница 1: ...l DIP switch The units can accommodate magnetic pickups logic sensors and NPN open collector sensors as well as switch contact closure sensors These units have a self test feature which checks all the...

Страница 2: ...n current sink or source sensor by connecting the appropriate terminals in common S3 on the APLPT PBLPT should be turned OFF since pull up or pull down resistors are already present in the counter The...

Страница 3: ...PT4 PBLPT4 the proper DIP switches must be selected before the unit is powered up To change a decimal point location the unit must be powered down the DIP switches changed then powered up The decimal...

Страница 4: ...ction Install line filters on the power input cable to the unit to suppress power line interference Install them near the power entry point of the enclosure The following EMI suppression devices or eq...

Страница 5: ...stort and not provide a water tight seal Recommended minimum panel thickness is 1 8 After the panel cut out has been completed and deburred carefully slide the panel gasket over the rear of the unit t...

Страница 6: ...basic formula applies to all units However for the APLPT5 PBLPT5 the D R must be converted to a base unit of measurement DMIT D R x P P S DMIT Display Multiplier Increment Total DR Desired Reading In...

Страница 7: ...talog or contact your local RLC distributor APLPT DESCRIPTION MODEL NO PART NUMBERS FOR AVAILABLE SUPPLY VOLTAGES ORDERING INFORMATION PBLPT500 PBLPT400 115 230 VAC Apollo 5 Digit Process Time Module...

Страница 8: ...or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be...

Отзывы: