Red Jacket Quick-Set AGUMP150S1 Скачать руководство пользователя страница 4

1

  Introduction

Red Jacket 4-inch diameter non-CPT UMPs are interchangeable except that the lengths vary dependent upon the 
model and inlet area. When changing the model of the installed UMP, be sure to check the length (ref. Table 5/
Figure 1) so that proper clearance off the tank bottom is maintained (4 to 5” [100 to 125mm] for standard and 
TRAPPER™ UMPs and 14” [355mm] for UMPs with a floating suction adapter.)

Red Jacket CPT UMP models (UMP200U20-2 and AGUMP20T20-2) can only replace non-CPT models if the 
entire system is upgraded to include the VSFC controller and PLLD pressure transducer.

Safety Precautions

The following safety symbols are used throughout this manual to alert you to important safety hazards and 
precautions.

EXPLOSIVE

Fuels and their vapors are extremely explosive if 
ignited.

FLAMMABLE

Fuels and their vapors are extremely flammable.

ELECTRICITY

High voltage exists in, and is supplied to, the device. 
A potential shock hazard exists.

TURN POWER OFF

Live power to a device creates a potential shock 
hazard. Turn Off power to the device and associ-
ated accessories when servicing the unit.

WARNING

 

indicates a hazardous situation 

which, if not avoided, could result in death or 
serious injury.

CAUTION

 

indicates a hazardous situation 

which, if not avoided, could result in minor or 
moderate injury.

WEAR EYE PROTECTION

Wear eye protection when working with pressurized 
fuel lines to avoid possible eye injury.

NOTICE

 is used to address practices not 

related to physical injury.

WEAR GLOVES

Wear gloves to protect hands from irritation or injury.

NO POWER TOOLS

Sparks from power tools (such as drills) can 
ignite fuels and their vapors.

NO SMOKING

Sparks and embers from burning cigarettes or pipes 
can ignite fuels and their vapors.

NO OPEN FLAMES

Open flames from matches, lighters, welding 
torches, etc. can ignite fuels and their vapors.

READ ALL RELATED MANUALS

Knowledge of all related procedures before you 
begin work is important. Read and understand all 
manuals thoroughly. If you do not understand a pro-
cedure, ask someone who does

TURN OFF CELL PHONES/PAGERS

Sparks from electronic devices in the vicinity of 
gasoline storage tanks could cause an explosion 
or fire resulting in bodily injury or death.

OFF

WARNING

CAUTION

NOTICE

Содержание Quick-Set AGUMP150S1

Страница 1: ...Manual No 577014 053 Revision D Replacement Instructions Red Jacket UMP Red Jacket Quick Set Submersible Pump...

Страница 2: ...f any damages and or shortages within 30 days of receipt of the shipment as stated in our Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Fax Bill of Lading to V R Customer Service at 800 234 5...

Страница 3: ...gure 7 UMP Bolts And Gasket 13 Figure 8 Verifying Pigtail s Female Connector Is Seated Properly In Discharge Head 14 Tables Table 1 Maximum Specific Gravity And Maximum Viscosity 4 Table 2 Electrical...

Страница 4: ...Turn Off power to the device and associ ated accessories when servicing the unit WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION indicates...

Страница 5: ...re your employees and any service contractors read and follow the instructions Follow the Regulations Applicable information is available in National Fire Protection Association NFPA 30A Code for Moto...

Страница 6: ...er s station WILL NOT shut off electrical power to the pump dispenser This means that even if you press a button on the console labeled EMERGENCY STOP ALL STOP PUMP STOP or something similar fuel may...

Страница 7: ...ted for the following fuel compatibility 100 Diesel 100 Gasoline Gasoline and up to 10 Ethanol 15 Methanol 20 MTBE 20 ETBE 20 TAME All models of The Red Jacket with the AG prefix are UL Listed for the...

Страница 8: ...144 224 5 17 5 AGUMP75S1 UMP75U1 3 4 60 1 200 250 6 5 25 2 9 3 6 14 9 18 2 17 7 21 9 410164 001 17 5 AGUMP150S1 UMP150U1 1 1 2 60 1 200 250 10 5 37 2 0 2 5 11 6 14 2 13 5 16 8 410164 002 25 X3AGUMP15...

Страница 9: ...1 1 2 60 1 200 250 10 5 33 2 8 3 4 6 8 8 2 9 4 11 3 410164 002 25 AGUMP200S1 3 AGUMPL200S1 3 UMP200U1 3 UMPL200U1 3 2 60 1 200 250 11 4 44 1 9 2 3 3 4 4 1 5 1 6 2 410164 003 40 AGUMP75S3 3 UMP75U3 3 3...

Страница 10: ...8 505 30 5 13 9 UMP75U17 3 AGUMP75U17 3 3 4 19 1 4 489 19 483 28 12 7 UMP150U1 AGUMP150S1 1 1 2 20 1 2 519 20 5 8 524 34 15 5 X3P150U1 X3AGUMP150S1 1 1 2 21 1 4 540 21 1 2 546 35 15 8 UMP150U3 3 AGUMP...

Страница 11: ...d down line from the pump close it 2 Remove the two extractable lock down nuts and discard them see Figure 2 The springs on the lock down studs between the extractable s flange and the manifold will p...

Страница 12: ...inding occurs during removal stop and determine the cause of the binding and correct the situation before proceeding with removal For all models with the RA suffix take care not to damage the powder c...

Страница 13: ...UMP retaining bolts Use hand force to push the UMP onto the discharge head If the UMP does not seat snug against the discharge head remove the UMP and correct the problem Fasteners are not metric use...

Страница 14: ...nd in the kit Apply anti seize also found in the kit to the lock down studs prior to nut and washer installation 15 Turn the air purge screw 2 3 turns counterclockwise see Figure 2 The air purge screw...

Страница 15: ...ssure to flow into the tank or back out Functional Element screw Confirm that the packer wiring compartment cover plug with lifting eyebolt is properly torqued at 50 ft lbs 70 N m Confirm that the lif...

Страница 16: ...indexing tab of the pigtail is seated in the notch of the discharge head Figure 7 UMP Bolts And Gasket 11 Pull the pigtail connector in the discharge head out far enough to see the o ring in the sidew...

Страница 17: ...nt 15 Replace the packer o ring and discharge Quad seal after lubricating them with petroleum based jelly 16 Reinstall the extractable portion into the tank aligning the positioning dowels of the mani...

Страница 18: ...ressure at line test port 50 psi 345 kPa maximum Excessive pressure above normal test pressure of 50 55 psi 345 380 kPa may damage check valve seat and other system components 4 After completion of li...

Страница 19: ...For technical support sales or other assistance please visit www veeder com...

Отзывы: