PRE-POWER CHECKS
TM-229 409 Page 20
Extreme 360
6-4. Input Pre-Regulator Module (MOD1)
Ref. 907 161 / 225 065-A
Y
Read and follow safety
before proceeding.
Y
Wear an earth grounded
wrist strap when perform-
ing pre-power checks. Re-
move wrist strap before
performing any checks or
procedures with power ap-
plied to the machine.
.
Board layout may differ from
that shown.
1
MOD1
Visually inspect MOD1 for dam-
age.
2
−
BUS
3
D12 Cathode
4
AC1
5
AC2
6
AC3
7
L1
8
L1-L2
9
TP1
10 +BUS
Check all measurements for Input
Pre
−
Regulator Module (MOD1)
(see Section 6-5).
If all measurements passed,
MOD1 is OK. Continue to the end
of the pre
−
power flowchart (see
Section 6-2).
1
Component Side Of Board
2
8
3
9
4
7
5
6
Test Equipment Needed:
10
6-5. Input Pre-Regulator Module (MOD1) Test Point Values
Input Pre-Regulator Module MOD1
DVM Positive Lead
DVM Negative Lead
DVM Diode
DVM Ohms
Boost IGBT
−
BUS
L1-L2
0.20 - 0.90
N/A
Boost IGBT
(w/Plug Removed From RC3)
D12 Cathode
−
BUS
N/A
100k
Boost Snubber Diode
L1-L2
TP1 (C6 and C7)
0.20 - 0.90
N/A
Input SCR
AC1
L1
0.20 - 0.90
N/A
Input SCR
AC2
L1
0.20 - 0.90
N/A
Input SCR
AC3
L1
0.20 - 0.90
N/A
Input Diode
−
BUS
AC1
0.20 - 0.90
N/A
Input Diode
−
BUS
AC2
0.20 - 0.90
N/A
Input Diode
−
BUS
AC3
0.20 - 0.90
N/A
Содержание EXTREME 360
Страница 4: ......
Страница 56: ...TM 229 409 Page 52 Extreme 360 Figure 8 1 Circuit for EXTREME 360 208 575 Volt Eff w LG250111A And Following...
Страница 57: ...TM 229 409 Page 53 Extreme 360 211 328 E...
Страница 59: ...TM 229 409 Page 55 Extreme 360 220 922 B...