TM-4412 Page 45
D502K 5+4
10-6. Filter Board PC6 Test Point Values
PC6 Voltage Readings
a) Tolerance –
±
10% unless specified
b) Reference – to circuit common
(lead 42) unless noted
c) Condition – no load
d) Process/Contactor Control switch
S6 in Weld Terminals Always On –
CC Stick position
Receptacle
Pin
Value
RC2
1
Not used
2
115 volt ac input with respect to pin RC2-10
3
24 volt ac input with respect to pin RC2-10
4
24 volt ac output with respect to pin RC2-10
5
Contactor control circuit, 24 volt ac input with contact closure to pin RC2-9 and closure on RC14 be-
tween pins A and B or pins I and J
6
Command reference, 10 volt dc input
7
Command common
8
Remote command signal output, 0 to +10 volts dc input from min to max of remote voltage/amperage
control
9
Circuit common for 24 and 115 volt ac contactor control circuits
10
Circuit common for 24 and 115 volt ac circuits