![Red-D-Arc D502K 5+4 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/red-d-arc/d502k-5-4/d502k-5-4_technical-manual_1428579023.webp)
TM-4412 Page 19
D502K 5+4
5-4.
Remote Voltage/Amperage Control
1
Remote 14 Receptacle RC14
Connect optional remote control to
RC14 (see Section 4-9).
0774 / Ref. 192 895-A / 802 311-A
Example: Combination Remote Amperage Control (Stick) With Remote On/Off Control
In Example:
Process = Stick (Using Remote On/Off)
Range = 125 to 400 A DC
Min = 125 A DC
Max = 400 A DC
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range
Control Not
Used In Remote
Stick Mode
Max (400 A DC)
Min (125 A DC)
Set Remote
Process
Example: Combination Remote Amperage Control (TIG) With Remote On/Off Control
In Example:
Process = TIG (Using Remote On/Off)
Range = 40 to 330 A DC
Percentage Of Range = 50%
Min = 40 A DC
Max = About 185 A DC (50% of 40 to 300)
Adjust Optional Remote Control
Set V/A
Adjust Switch
Set Range
Set Control
Max (185 A DC)
Min (40 A DC)
Set Remote
Process
1