6-2. Description Of Front Panel Controls (See Section 6-1)
Engine Starting Controls
1
Engine Control Switch
Use switch to start and stop engine.
To Start
:
NOTICE
−
Do not use ether. Using ether
voids warranty.
If engine does not start within 15 sec-
onds, release switch and let engine come
to a complete stop before attempting re-
start.
Turn Engine Control switch to Start. Release
Engine Control switch when engine starts.
To Stop
: turn Engine Control switch to Off
position.
Engine Gauges And Meters
To read gauges with engine off, turn
Start/Preheat switch to Preheat position.
2
Engine Fuel/Hour Gauge
Use meter to monitor engine running time for
scheduling maintenance.
Use gauge to check fuel level. Engine stops
if fuel level is low.
To check fuel level when engine is not running
place Engine Control switch in Preheat posi-
tion then default back to neutral position.
See Section 6-5 for complete fuel/hour gauge
information.
3
Engine Temperature Gauge
Normal temperature is 180 - 203
°
F (82 - 95
°
C). Engine stops if temperature exceeds 220
°
F (104
°
C).
4
Engine Oil Pressure Gauge
Normal pressure is 30
−
60 psi (207
−
414
kPa). Engine stops if pressure is below 10 psi
(69 kPa).
Weld Controls
Max OCV Control Circuit:
This unit has
a max OCV control circuit that resets Am-
perage Adjust control R1 to maximum
when the arc breaks. When an arc is
struck, weld output control returns to the
R1 front panel or combination front panel/
remote control setting. The Amperage
Adjust control adjusts amperage only
when welding and does not adjust open-
circuit voltage.
The max OCV circuit is disabled when
the Stick/TIG Selection switch is in
Scratch Start TIG position (see item 7).
5
Ampere Range Switch
NOTICE
−
Do not switch under load.
Use switch to select weld amperage range.
For most welding applications, use lowest
amperage range possible to help prevent arc
outages.
6
Amperage Adjust Control
Control adjusts amperage within range se-
lected by Ampere Range switch. Weld output
would be about 168 A DC with controls set as
shown (50% of 110 to 225 A).
The numbers around the control are for
reference only and do not represent an
actual percentage value.
7
Stick/TIG Selection Switch
Use switch to disable the max OCV circuit
and the arc drive (dig) circuit for scratch start
TIG welding (see max OCV note under Weld
Controls).
When switch is in the Stick position, the max
OCV circuit resets Amperage Adjust Control
R1 to maximum when the arc breaks.
Also in the Stick position, the arc drive (dig)
circuit provides additional amperage during
low voltage (short arc length conditions) to
prevent “sticking” electrodes.
When switch is in Scratch Start TIG position,
the max OCV and arc drive (dig) circuits are
disabled and OCV changes when the control
is adjusted.
8
Amperage Adjust Switch And Remote
Amperage Adjust Receptacle
Connect optional remote control to RC13
(See Section 5-12). Use switch to select front
panel or remote amperage control. For re-
mote control, place switch in Remote position
and connect remote control to Remote Am-
perage Adjust receptacle RC13 (see Sec-
Weld Meters
9
AC/DC Voltmeter
Voltmeter displays voltage at the weld output
terminals, but not necessarily the welding arc
due to resistance of cable and connections.
10 AC/DC Ammeter
Ammeter displays amperage output of the
unit.
Содержание D502DX 5+4
Страница 2: ......
Страница 35: ...OM 224 690 Page 31 6 5 Fuel Hour Gauge Descriptions...
Страница 48: ...OM 224 690 Page 44 SECTION 9 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For CC Welding Generator...
Страница 49: ...OM 224 690 Page 45 237 428 A...
Страница 72: ...OM 224 690 Page 68 Notes...
Страница 73: ...OM 224 690 Page 69 Notes...
Страница 74: ...OM 224 690 Page 70 Notes...