OM-224 690 Page 30
6-3. Remote Amperage Control (Optional)
1
Remote Amperage Adjust
Receptacle RC13
Connect optional remote control to
Example: Combination Remote Amperage Control (Stick)
Adjust Optional Remote Control
Set Switches
Set Range
Set Control
Ref. 236 984-A / Ref. 804 168
In Example:
Range = 110 to 225 A DC
Percentage Of Range = 50%
Max = About 168 A DC (50% of 110 to 225)
Max (168 A DC)
Min (90 A DC)
1
6-4. Weld Control/Arc Condition Information Label
Set weld controls as shown to
achieve softer or stiffer arc condi-
tions for different applications.
212 944-B