background image

    control wheels of the housing begin to slip, use a soft dry cloth to wipe away any oil and  

other contaminates that may cause the loss of friction from both the camera functions and 

O-rings.

Flash Up Lever

The housing  Flash   Up Lever  is  designed   to turn   the  camera's  flash  on  ONLY. When 

installing or removing camera pull set Flash Up Lever out and the middle position. After 

installing push Flash Up Lever in and the up so the internal lever is in the proper position.

Flash Close Dial

The   CANON   G1XMkII   camera's   on-board   strobe   does   NOT  close   automatically   when 

camera is turned OFF. Be sure to manually close the strobe using the Flash Close Dial 

before removing camera from housing..

Zoom Lever Lock Screw

Use the Zoom Lever Lock Screw to lock Zoom Lever after setting wide focus when using 

an optional wide-angle port and lens. Accidentally zooming in may cause damage to the 

port and lens.  

Note: When not in use, unscrew the Zoom Lever Lock Screw to the up 

position so the screw head rests stationary against the retainer above it. 

Strobe Mask-External Strobe Connection Mount Screw Socket

For external strobes use Strobe Mask-External Strobe Connection Mount and screw to 

connect bear fiber-optic cable (INON) or plug (SEA&SEA). 

Port Lock Button

Use  to  remove  the  Lens  Port.  While  pressing  the   Port Lock   Button,   rotate  Lens  Port 

clockwise until it stops then pull Lens Port off of housing.

 

Please refer to camera manual for explanation of button and dial functions.

 

Some housing dials are designed to turn the corresponding camera dials back and forth 

via friction from the O-ring that come in contact with the camera dials inside the housing. 

Should   the   dials   begin   to   slip,   use   a   soft   dry   cloth   to   wipe   away   any   oil   and   other 

contaminates that may cause the loss of friction from both the camera functions and O-

rings.

OPENING AND CLOSING THE BACK COVER

 

Please do the following operations in a clean area with low humidity and dust.

To OPEN, press Lock Lever while pulling Secure-Latch away from housing main body.

To CLOSE, press Secure-Latch into place making sure the latch on the underside is properly 

placed in the Secure-Latch groove attached to the main housing body. Push into the locked  

position. Double check to make sure it is firmly locked into place.

4.

Содержание WHC-G1XMKII

Страница 1: ...Canon PowerShot G1X Mark II Underwater Housing Recsea WHC G1XMkII MANUAL Please read this manual before use NTF CORPORATION UH Division http www seatool net...

Страница 2: ...t sunlight CAUTION To prevent water leakage and damage DO NOT disassemble or modify this housing Do not store the housing in areas of high humidity high or low temperatures or areas of extreme tempera...

Страница 3: ...on control Variety of supported RECSEA original options PACKAGE CONTENTS Be sure all items listed here are included WHC G1XMkII UW Housing M67 Port Adapter Strobe Mask External Strobe Diffuser Connect...

Страница 4: ...the camera dials back and forth via friction from the O rings that come in contact with camera functions inside the housing When installing or removing camera pull Mode Dial up After installing be su...

Страница 5: ...it Strobe Mask External Strobe Connection Mount Screw Socket For external strobes use Strobe Mask External Strobe Connection Mount and screw to connect bear fiber optic cable INON or plug SEA SEA Port...

Страница 6: ...ng and Port O RING MAINTENANCE prior to installation Please conduct the following operations in a clean area with low humidity and dust Camera can be inserted with lens port attached 1 Check camera se...

Страница 7: ...the locked position Double check to make sure the Secure Latch is securely locked into place 9 Fill a bucket with water and perform Pre Dive Check Immerse Housing with Port properly attached several t...

Страница 8: ...ter from falling into the housing and onto camera 1 While pressing the Port Lock Button rotate Lens Port clockwise until it stops 2 Pull Lens Port outwards away from housing to remove INTERNAL AND EXT...

Страница 9: ...soline and benzine etc 7 Perform O RING GREASING MAINTENANCE as instructed below before re installing O RING GREASING MAINTENANCE 1 CAUTION DO NOT use silicone grease other than that provided by Seato...

Страница 10: ...g O ring groove and O ring surface maintenance and greasing every time you open close the housing Please pay close attention and make sure the O rings are not twisted or bulging free of any contaminan...

Страница 11: ...y STG 06W2 POM Left Hand Single Grip Tray Assembly STG 05L2 AL Dual Grip Tray Assembly STG 05W2 AL Left Hand Single Grip Tray Assembly STG 05JL2 AL Dual Grip Extension STG 05JWEP AL INON Tray Adapter...

Страница 12: ...on of this product including those related to lost profits or any related expenses Seatool Recsea will stock parts necessary for repair for five 5 years from stop of production This product uses some...

Страница 13: ...MEMO...

Страница 14: ...MEMO...

Страница 15: ...MEMO...

Страница 16: ...Product Number WHC G1XMkII Dealer Name Serial Number Dealer Stamp your company name and contact information purchase date model and serial number Seatool Recsea Manufacturing Sales NTF CORPORATION UH...

Отзывы: