background image

between camera and inside of housing. If camera is not inserted correctly, buttons, dials, 

and levers may not function properly.

NOTE: 

The internal bezels of the housing  Step Ring and Continuous Ring Dials will cause 

some resistance. Hold housing in both hands and use thumbs to gently press the left bottom 

and right top corners of the camera simultaneously to slowly and gently push camera forward 

into housing until camera is properly seated.

5. Push housing Mode Dial down and into place.

6. Turn camera on and test housing Mode Dial, Step Ring Dial, Continuous Ring Dial, Flash 

Up Lever, and Flash Close Dial to assure they are functioning properly.

7. Carefully   place   Camera   Extraction   Tabs  at   side   of   camera   inside   housing   as   shown 

shown below.

8. After performing O-ring maintenance, carefully close back cover making sure nothing is 

caught between the back cover and main body or the Secure-Latch and housing. Push 

Secure-Latch   into   the   locked   position   making   sure   the   Lock   Lever   is   in   the   locked 

position. Double check to make sure the Secure-Latch is securely locked into place.

9. Fill   a   bucket   with   water   and   perform   Pre-Dive   Check.   Immerse   Housing   (with   Port 

properly attached) several times, starting with short intervals, gradually lengthening time, 

checking for water leakage after each interval. Be sure to test functions at this time.

10. When entering water use a method of water entry that protects the housing from shock, 

which  can  cause  water  leakage.  If  at  all  possible  have  Housing  handed  to  you  after 

entering the water.

REMOVING CAMERA

CAUTION!

  After use in water, water will remain in gaps between housing, back cover and 

Secure-Latch. Wipe any water off housing with a soft dry towel to prevent water from falling 

on camera.

1. Pull housing Mode Dial outward away from housing.

2. Use housing Flash Close Dial to manually close camera's on-board strobe is up close.

3. Open the back cover as instructed above.

4. Simultaneously and gently pull Camera Extraction Tabs to until camera lens is completely 

dislodged from Lens Port and remove camera from housing.

INSTALLING LENS PORT

Please   perform   proper   Lens   Port   Inner   Surface   O-RING   MAINTENANCE   prior   to 

installation.

6.

Содержание WHC-G1XMKII

Страница 1: ...Canon PowerShot G1X Mark II Underwater Housing Recsea WHC G1XMkII MANUAL Please read this manual before use NTF CORPORATION UH Division http www seatool net...

Страница 2: ...t sunlight CAUTION To prevent water leakage and damage DO NOT disassemble or modify this housing Do not store the housing in areas of high humidity high or low temperatures or areas of extreme tempera...

Страница 3: ...on control Variety of supported RECSEA original options PACKAGE CONTENTS Be sure all items listed here are included WHC G1XMkII UW Housing M67 Port Adapter Strobe Mask External Strobe Diffuser Connect...

Страница 4: ...the camera dials back and forth via friction from the O rings that come in contact with camera functions inside the housing When installing or removing camera pull Mode Dial up After installing be su...

Страница 5: ...it Strobe Mask External Strobe Connection Mount Screw Socket For external strobes use Strobe Mask External Strobe Connection Mount and screw to connect bear fiber optic cable INON or plug SEA SEA Port...

Страница 6: ...ng and Port O RING MAINTENANCE prior to installation Please conduct the following operations in a clean area with low humidity and dust Camera can be inserted with lens port attached 1 Check camera se...

Страница 7: ...the locked position Double check to make sure the Secure Latch is securely locked into place 9 Fill a bucket with water and perform Pre Dive Check Immerse Housing with Port properly attached several t...

Страница 8: ...ter from falling into the housing and onto camera 1 While pressing the Port Lock Button rotate Lens Port clockwise until it stops 2 Pull Lens Port outwards away from housing to remove INTERNAL AND EXT...

Страница 9: ...soline and benzine etc 7 Perform O RING GREASING MAINTENANCE as instructed below before re installing O RING GREASING MAINTENANCE 1 CAUTION DO NOT use silicone grease other than that provided by Seato...

Страница 10: ...g O ring groove and O ring surface maintenance and greasing every time you open close the housing Please pay close attention and make sure the O rings are not twisted or bulging free of any contaminan...

Страница 11: ...y STG 06W2 POM Left Hand Single Grip Tray Assembly STG 05L2 AL Dual Grip Tray Assembly STG 05W2 AL Left Hand Single Grip Tray Assembly STG 05JL2 AL Dual Grip Extension STG 05JWEP AL INON Tray Adapter...

Страница 12: ...on of this product including those related to lost profits or any related expenses Seatool Recsea will stock parts necessary for repair for five 5 years from stop of production This product uses some...

Страница 13: ...MEMO...

Страница 14: ...MEMO...

Страница 15: ...MEMO...

Страница 16: ...Product Number WHC G1XMkII Dealer Name Serial Number Dealer Stamp your company name and contact information purchase date model and serial number Seatool Recsea Manufacturing Sales NTF CORPORATION UH...

Отзывы: