RECOUP EASYFIT+ Скачать руководство пользователя страница 4

Page 4 

1.   To  retrofit  the  Recoup    below  the  shower  system 

installed must have a thermostatic mixer. This can be either 

be deck mounted onto the bath or wall mounted above it.

2.   To  start  retrofitting  the  Recoup    remove  the  bath 

panel  from  the  side  of  the  bath  along  with  any  structure 

supporting the panel that restricts access.

SETTING UP TO RETROFIT THE RECOUP

5.   If required remove part of the added support to allow access 

during the installation.

6.  Look at the water and waste pipe connections and identify 

the waste water trap, the waste water out pipe, the hot water 

pipe to the shower and the mains cold water pipe to the shower.

3.   If the bath has a central foot installed this will need to be 

removed to accommodate the .

4.   If  a  central  supporting  foot  is  removed,  then  alternative 

raised support should be installed that will bridge over the 

area where the needs to be positioned.

7.   Disconnect the waste water trap from the bath along with 

the  waste  water  pipes  to  where  they  connect  to  the  SVP 

soil pipe.

8.   Ensure that the mains cold water has been switched off at 

the stopcock then separate the pipe for the mains cold water 

to the shower.

Содержание EASYFIT+

Страница 1: ...Easyfit must be located within the heating envelope of the building The Easyfit must be installed with consideration to the most recent Approved document Part H of the Building Regulations for preven...

Страница 2: ...e Not supplied Double check valve Not supplied Shut off valve Not supplied Shut off valve Not supplied Shut off valve Not supplied Shut off valve Not supplied MAINS COLD WATER MAINS COLD WATER PREHEAT...

Страница 3: ...Page 3 Installation with bath shower drain at the opposite end to the SVP soil waste Installation with bath shower drain at the same end as the SVP soil waste...

Страница 4: ...and waste pipe connections and identify the waste water trap the waste water out pipe the hot water pipe to the shower and the mains cold water pipe to the shower 3 If the bath has a central foot inst...

Страница 5: ...This is so that the shower waste water flows through the unit from one end to the other 11 The Easyfit incorporates symmetrical connections at either end Orientate the unit whichever way best suits fo...

Страница 6: ...ater at the higher end of the Easyfit 22 Connect a full flow shut off valve not supplied to assist with easy removal and maintenance 19 Connect the opposite end of the female half inch BSP connector t...

Страница 7: ...n the mains cold water feed to start the cold water flow into the Easyfit 30 Open the full flow shut off valve on the preheated water pipe to start the flow from the Easyfit 27 When the highest point...

Страница 8: ...ntenance required for the RECOUP Easyfit is very minimal however it is recommended to clean the unit periodically to avoid any reduction in efficiency This cleaning will remove any build up of soap an...

Страница 9: ...ould be registered to comply with SAP requirements Registration can be completed by filling in a downloadable paper based design and installation checklist returning it to RECOUP with copies completed...