Operation
5
BAL_FlowControl_EN_1V3_REC_121-006454644
17 / 28
5
Operation
5.1
BDE-D FC and key functions
C
E
002 / 050
The electronic operating unit BDE-D FC is an input and output unit for the con-
trol and parameterization of the number of persons. The LCD display with
background illumination provides information about the status with symbols
and plain text. Messages are shown on the display as text information.
Button
Designation
Function
ON / OFF
– Switch system on / off
BACK
– Exit menu item and change to the previous menu item
EXIT ONLY
– Door opens only by activating the triggering device on the inside of the
door (radar).
MINUS
– Navigation up when selecting the menu items
INFO
– The INFO button is the access to the settings. Different settings are dis-
played depending on the authorization level
(see chapter "Select Permis-
sion Level")
PLUS
– Navigation down when selecting menu items
NOTICE
Menu display: In this area, the keys have the function printed above or below the keys (navig-
ation information).
Example: The INFO button has the function "E" (Enter / confirm input).
Button
Designation
Function
E
ENTER
– Select menu item
– Confirm entries within the menu display
C
CANCEL
– Cancel entries within the menu display without saving
Display
Symbol
Designation
Function
CURRENT
– Current number of people inside the building.
MAXIMUM
– Maximum number of persons allowed inside the building.