Technical data
4
BAL_FlowControl_EN_1V3_REC_121-006454644
15 / 28
4
Technical data
System Specifications
Counting accuracy:
> 99%
Counting technology:
Time-of-Flight 3D
Counting statistics:
Total Counter
Operation counter (15 entries)
Maximum number of sensors (combined):
4
Configuration layouts for several entrance/exit doors:
Yes
Configurable count values:
Yes (Actual and maximum number of persons is ad-
justable)
On/Off button:
Yes
Operating unit:
BDE-D FC
Interaction with sliding doors:
Yes, all record doors plus third-party doors with radar
sensors (relay contacts)
Check compatibility with bus-connected radar sensors
on third-party doors
Mounting position LED strips:
Exterior
Mounting position electronics:
Interior
Mounting position sensor:
Interior
Dimensions
Opening width A:
max. 2200 mm at 3000 mm installation height
Passage height G:
variable
Total height J:
variable
Installation height of sensor:
2100 - 3000 mm
Min. object height to be counted:
1300 mm
Electrical connection data
Mains voltage (input):
110 - 230 V AC, 50-60 Hz
System voltage Peripherals:
24 V DC
Power consumption
System
Max. 60 W
LED Strips
5 W per meter
Sensor
6 W per sensor
Control box
3 W
Cable length, -extensions
Recommended cross-section LED strips
4 x 0.5mm²
Max. Cable length LED-strips
100 m
Max. Cable length BDE-D FC
80 m
Max. Cable length between first and last sensor:
With 2 sensors
120 m
With 3 sensors
100 m
With 4 sensors
60 m
VoiceBox (optional)
Mains voltage:
12 - 24 V
Power rating sound module:
10 W at 2 – 16 Ω
Potential-free inputs (voice output):
4
Speaker Output power:
25 W