background image

©2016 ReconRobotics 

7  

 

 

Instructions for Use: Chargers

Instructions for Use: Chargers

 

 

 

Reading Charge Indicator Lights on Battery Chargers 

Your kit may include one or both of these chargers. When plugged into an active 
power source, the indicator LEDs will display the following charge states: 

*Battery not included. 

 

AC Dual DC Battery 
Charger 

BA5590/BB2590 Field 
Charger* 

Green 

Light 

Fully charged 
OR 
Not plugged into OCU II/
robot 

Fully charged 
 
NOTE: LED light may shut off 
after charging is complete 

Red Light 

Charging 
 

Charging 

No Light 

Not receiving power from 
outlet 

Not plugged into OCU II/robot 
OR  
Charging is complete (fully 
charged) 

Blinking 

Light 

Charger is connected incor-
rectly and is not charging the 
robot/OCU II. Unplug eve-
rything and retry (refer to 
page 8 for instructions). 

N/A 

©2016 ReconRobotics 

8  

 

 

 

 

 

 

 
AC Dual DC Battery Charger 

1.  Turn off OCU II and insert activation pin into robot to deactivate before charging. 

2.  Plug AC electrical cord into the charger. (NOTE: charger 

must

 be connected to a 

power source before robot or OCU II for proper operation) 

3.  Plug AC electrical cord into the proper country-specific AC wall socket (120-240 

VAC). 

4.  Plug the appropriate charger cords into the OCU II and robot. Ensure connecting 

plugs are not bent during insertion or removal. Ensure that the red dot on the 
connecting plug is aligned with the red line on the robot when inserting (see image 
at right). 

5.  Remove robot and OCU II from charger when charging is complete. 

 
 
 

BA5590/BB2590 Field Charger 

1.  Turn off OCU II and insert activation pin into robot to deactivate before charging. 

2.  Plug electrical cord into a 5590 or 2590 battery. 

3.  Plug the appropriate charger cords into the OCU II and robot. Ensure connecting 

plugs are not bent during insertion or removal. Ensure that the red dot on the 
connecting plug is aligned with the red dot on the robot when inserting (see image 
above). 

4.  Remove robot and OCU II from charger when charging is complete. 

General Instructions & Recommendations 



Place the chargers in a cool, ventilated, fire-safe area.  



Charge your robot and OCU II once per month, even if they were not used. This 
will keep the batteries topped off to ensure the robot is always ready for immediate 
deployment. 

 

To prevent battery damage, DO NOT 
use any chargers other than those 
supplied by ReconRobotics. 

The charger plugs are NOT interchangeable. 
Inserting the wrong plug into the robot or OCU II 
could result in permanent damage. 

Содержание Scout XL

Страница 1: ...u are experiencing and request a Return Material Authorization RMA tracking number In addition to your original sales receipt you will need to provide the unit s serial number your return shipping address email address and a daytime telephone number ReconRobotics Inc 5251 W 73rd Streeet Ste A Edina MN 55439 Phone 1 866 697 6267 or 952 935 5515 Fax 952 935 5508 Website www reconrobotics com For cus...

Страница 2: ...he buyer assumes all risks associated with lithium polymer batteries If you do not agree with these conditions please return the robot kit to ReconRobotics Do not attempt to disassemble or modify the robot or OCU II This may cause an electric shock fire or system failure Do not insert any foreign objects inside the robot or OCU II This may cause electric shock fire or system failure Do not immerse...

Страница 3: ... warranty and or Annual Maintenance Plans Keep loose clothing and hair away from the robot Considerations for charging Always charge the robot with the activation pin inserted Always keep the OCU II turned off while charging Always charge in a cool ventilated fire safe area Do not leave system unattended while charging Always use a proper country specific AC socket 120 240 VAC with the battery cha...

Страница 4: ...ne or email 5 Serial number of the product that is experiencing difficulties Our technical staff will attempt to troubleshoot and resolve the problem If repair service is needed we will set up an RMA Return Material Authorization and ar range for shipment of your equipment to our US repair facility Standard turnaround time for repair is under one week after receipt If your issue cannot be resolved...

Страница 5: ... it really does Ensure that the IR blister is free of dust or debris by wiping it with a soft towel The robot or OCU II doesn t seem to be holding a full battery charge What can be done If you feel that your Recon Scout XL robot or OCU II is not running for its complete battery life on a full charge there is a simple test you can run to check the performance Fully charge your robot and OCU II refe...

Страница 6: ...n have several possible causes The robot may be out of range The robot may be low on power or deactivated The robot or OCU II may be experiencing interference caused by environmental factors e g other radio devices in the area or proximity to metal The charge indicator lights do not light up when the robot or OCU II is connected to the battery charger Refer to page 7 for instructions on how to rea...

Страница 7: ...deo Out Capabilities OCU II Audio Video Out Capabilities Audio Output The OCU II is capable of receiving audio transmitted from the Recon Scout XL robot To listen plug the provided volume control adaptor into the appropriate jack on the left hand side of the OCU II Then plug headphones into the volume control adaptor Headphones approved for Apple or Android devices will not work with the provided ...

Страница 8: ... 2 and one on channel A will interfere with each other and not work well in the same environment Basic Deployment Instructions 1 Charge robot or OCU II if needed 2 Rotate OCU II antennas to an upright position 3 Switch OCU II on 4 Pull pin from robot Confirm that robot is broadcasting video and accepting command from the OCU II before deploying 5 If using headphones with a Recon Scout XL robot plu...

Страница 9: ...t off the IR Blister to ensure the sensor is clear Parts Replacement The parts and tools supplied in a Field Maintenance Kit FMK allow you to replace the following parts on your Recon Scout XL robot Antennas Wheels Tail Activation Pin 2016 ReconRobotics 6 Setting up the OCU II Rotate antennas to an upright position as shown The operator may rotate the antennas up or down as needed to receive the m...

Страница 10: ...fic AC wall socket 120 240 VAC 4 Plug the appropriate charger cords into the OCU II and robot Ensure connecting plugs are not bent during insertion or removal Ensure that the red dot on the connecting plug is aligned with the red line on the robot when inserting see image at right 5 Remove robot and OCU II from charger when charging is complete BA5590 BB2590 Field Charger 1 Turn off OCU II and ins...

Отзывы: