Ex-BA line sensor
27
Doc 141917 | Rev. 03
[Type codes of the models]
NOTE
The following sensors (or sensors that are not isolated) are considered not isolated or earthed in
accordance with IEC/EN 60079-11:
#
Ø 3 mm; more than 4 internal conductors
#
Ø < 3 mm
#
Ø 3 mm; more than 6 internal conductors
For technical safety reasons these sensors must be connected to the equipotential bonding of the system
throughout the complete length of the intrinsically safe electrical circuit. The special conditions in
accordance with IEC / EN 60079-14 must be observed.
The permissible process temperature [°C] depends on the maximum input power (P
i
) and the
temperature class.
T
process
= T
max
– P
i
x R
th
Power ratings
R
th
= 281 at WR14-*150-**** and WR14-*200-**** (not isolated):
Temperature class
P
i
= 20 mW
P
i
= 50 mW
P
i
= 250 mW
P
i
= 500 mW
P
i
= 750 mW
T1 (450°C)
434
426
369
300
229
T2 (300°C)
284
276
219
150
79
T3 (200°C)
189
181
124
55
/
T4 (135°C)
124
116
59
/
/
T5 (100°C)
89
81
24
/
/
T6 (85°C)
74
66
9
/
/
Tab. 11: WR14 – Rth 281 power ratings
R
th
= 183 at WR14-*300-****:
Temperature class
P
i
= 20 mW
P
i
= 50 mW
P
i
= 250 mW
P
i
= 500 mW
P
i
= 750 mW
T1 (450°C)
436
430
394
348
302
T2 (300°C)
286
280
244
198
152
T3 (200°C)
191
185
149
103
57
T4 (135°C)
126
120
84
38
/
T5 (100°C)
91
85
49
3
/
T6 (85°C)
76
70
34
/
/
Tab. 12: WR14 – Rth 183 power ratings