8
Installation of cables
Wiring
of the
sensor
should be routed separately or screened from heavy conductor lines, as in extreme
cases inductive peak voltages can destroy the sensors despite the integrated protective circuit. Screened
cable or twisted lines are recommended, especially for longer cable runs > 5 m.
Units with strong fields nearby
, e. g. high power walkie-talkies, or noise sources in the lower frequency
range, e. g. long, middle or short wave transmitters should not be operated close to the sensors or additional
measures have to be taken in order to eliminate incorrect operation.
Pin connection
Pin connection for pluggable sensors (top view)
4
1
3
2
EasyTeach chart
The EasyTeach chart is used for optical menu navigation. They
illustrate the flashing behaviour of the LED.
Sensor free, ready for automatic adjustment
Sensor is in the adjustment phase (placing the sensor on the bottom of the container)
Working area, sensor active
Sensor detects leakage
Sensor has a slight deviation of its position, e.g. sensor is tilted
EasyTeach chart
Output A1 = normally open /
Output A2 = normally closed
EN
LED
Output A1
Output A2
Free hold
flashing / 1 Hz
low
high
Place on container bottom
flashing / 5 Hz
low
high
Ready for use
high
high
Leakage detection
high
low
Change of position
flashing / 2 Hz
low
high
Switching function of the outputs