14
REC Installation Manual - REC Alpha Panels - IEC 61215 /61730
Rev 13 - 11.22
290 mm
730 mm
410 mm
300 mm
200 mm
0
90 mm
0
300 mm
200 mm
0
300 mm
200 mm
0
300 mm
200 mm
0
520 mm
290 mm
730 mm
410 mm
0
90 mm
520 mm
570 mm
570 mm
CAUTION
The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to be rated to that load (fig. 8).
If the panel is secured in zones with different load values, it is rated to the lowest load value only.
Fig. 8: Clamping of REC Alpha Pure-R Series panels using short rails
MOUNTING REC ALPHA PURE-R SERIES PANELS WITH SHORT RAILS
A short rail (or other short support structure) has a minimum length of 25 mm and does not span the complete underside of a panel.
Legend
Clearance Gap
Clamping zone
20-40 mm
40-60 mm
>60 mm
Test Load
(Design Load)
Test Load
(Design Load)
Test Load
(Design Load)
Rail length under
module
25 - 100 mm
Min.
25 m
m
Max.
100 mm
90 - 290 mm
X
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
290 - 410 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+3000 Pa / -3000 Pa
(+2000 Pa / -2000 Pa)
410 - 520 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
520 - 570 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+3600 Pa / -2400 Pa
(+2400 Pa / -1600 Pa)
570 - 730 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
0 - 200 mm
X
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
200 - 300 mm
X
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
Rail length under
module
100 - 200 mm
Min.
100
mm
Max.
200 mm
90 - 290 mm
X
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
290 - 520 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
520 - 570 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
+3000 Pa / -3000 Pa
(+2000 Pa / -2000 Pa)
570 - 610 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
610 - 730 mm
+1200 Pa / -1200 Pa *
(+800 Pa / -800 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
+2400 Pa / -2400 Pa
(+1600 Pa / -1600 Pa)
0 - 200 mm
X
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
200 - 300 mm
X
+800 Pa / -800 Pa *
(+533 Pa / -533 Pa)
+1600 Pa / -1600 Pa *
(+1066 Pa / -1066 Pa)
Installations with a clearance gap between the uppermost part of the roof and lowest part of the panel (i.e., frame) with a clearance
gap of <20 mm are not permitted. Once a module is secured in each of the 4 zones (fig. 2), additional clamps, i.e., ≥5, may be freely
located on panel frame without affecting the warranty. Loads marked with a
*
were not certified as part of IEC 61215/61730
testing; these have been evaluated by REC’s internal testing process.