background image

12

REC Installation Manual - REC Alpha Panels  - IEC 61215 /61730
Rev 13 - 11.22 

Ref: PM-IM-23

290 mm 

730 mm

410 mm

 

300 mm

 

200 mm

0

90 mm

0

300 mm

200 mm

0

300 mm

200 mm

0

300 mm

200 mm

0

520 mm

290 mm 

730 mm

410 mm 

0

90 mm

520 mm

570 mm

570 mm

CAUTION

The center point of each clamp and the minimum grip length must be fully located in the same clamping zones to be rated to that load (fig. 6).  

If the panel is secured in zones with different load values, it is rated to the lowest load value only.

Rail positioning

Rail positioning

Fig. 6:  Clamping of REC Alpha Pure-R Series panels with rails parallel to short side of the panel

Legend

Clearance Gap

Clamping zone

20-40 mm

40-60 mm

>60 mm

Test Load

(Design Load)

Test Load

(Design Load)

Test Load

(Design Load)

90 - 290 mm

X

+2400 Pa / -2400 Pa *

(+1600 Pa / -1600 Pa)

+2400 Pa / -2400 Pa

(+1600 Pa / -1600 Pa)

290 - 410 mm

+1800 Pa / -1800 Pa *

(+1200 Pa / -1200 Pa)

+4200 Pa / -2400 Pa

(+2800 Pa / -1600 Pa)

+5400 Pa / -2400 Pa

(+3600 Pa / -1600 Pa)

410 - 520 mm

+1800 Pa / -1800 Pa *

(+1200 Pa / -1200 Pa)

+6200 Pa / -3000 Pa

(+4133 Pa / -2000 Pa)

+7000 Pa / -3000 Pa

(+4666 Pa / -2000 Pa)

520 - 570 mm

+1200 Pa / -1200 Pa *

(+800 Pa / -800 Pa)

+3000 Pa / -2400 Pa

(+2000 Pa / -1600 Pa)

+5400 Pa / -2400 Pa

(+3600 Pa / -1600 Pa)

570 - 730 mm

+2400 Pa / -2400 Pa

(+1600 Pa / -1600 Pa)

+2400 Pa / -2400 Pa

(+1600 Pa / -1600 Pa)

+2400 Pa / -2400 Pa

(+1600 Pa / -1600 Pa)

0 - 200 mm

X

+800 Pa / -800 Pa *

(+533 Pa / -533 Pa)

+800 Pa / -800 Pa *

(+533 Pa / -533 Pa)

200 - 300 mm

X

+800 Pa / -800 Pa *

(+533 Pa / -533 Pa)

+1600 Pa / -1600 Pa *

(+1066 Pa / -1066 Pa)

Installations with a clearance gap between the uppermost part of the roof and lowest part of the panel (i.e., frame) with a clearance 

gap of <20 mm are not permitted. 

 

Once a module is secured in each of the 4 zones (fig. 2), additional clamps, i.e., ≥5, may be freely located on panel frame without 
affecting the warranty. Loads marked with a 

*

 were not certified as part of IEC 61215/61730 testing; these have been evaluated by 

REC’s internal testing process.

Lo

ng

 S

id

M

ou

nt

in

g

Sh

or

t S

id

e

M

ou

nt

in

g

Rail position

Rail position

INSTALLATION OF REC ALPHA PURE-R SERIES PANELS

MOUNTING WITH CONTINOUS RAILS PARALLEL TO SHORT SIDE OF THE PANEL

A continous rail (or other support structure) spans the complete underside of the panel.

Legend

Clearance Gap

Clamping zone

20-40 mm

40-60 mm

>60 mm

Test Load

(Design Load)

Test Load

(Design Load)

Test Load

(Design Load)

90 - 730 mm

+1200 Pa / -1200 Pa *

(+800 Pa / -800 Pa)

+1600 Pa / -1600 Pa *

(+1066 Pa / -1066 Pa)

+2400 Pa / -2400 Pa

(+1600 Pa / -1600 Pa)

0 - 200 mm

X

+1200 Pa / -1200 Pa *

(+800 Pa / -800 Pa)

+1600 Pa / -1600 Pa *

(+1066 Pa / -1066 Pa)

200 - 300 mm

X

+800 Pa / -800 Pa *

(+533 Pa / -533 Pa)

+2400 Pa / -2400 Pa

(+1600 Pa / -1600 Pa)

Installations with a clearance gap between the uppermost part of the roof and lowest part of the panel (i.e., frame) with a clearance 

gap of <20 mm are not permitted. 
Once a module is secured in each of the 4 zones (fig. 2), additional clamps, i.e., ≥5, may be freely located on panel frame without 
affecting the warranty. Loads marked with a 

*

 were not certified as part of IEC 61215/61730 testing; these have been evaluated by 

REC’s internal testing process.

Содержание Alpha Pure Series

Страница 1: ...FOR ALL REC ALPHA SOLAR PANELS CERTIFIED ACCORDINGTO IEC 61215 IEC 61730 STANDARDS rec Alph panels Installation Manual REC Alpha Pure Series REC Alpha Pure R Series Rev 13 11 22...

Страница 2: ...ure Series panels with short rails 11 Installation of REC Alpha Pure R Series panels 12 Mounting with continous rails parallel to short side of the panel 12 Mounting REC Alpha Pure R Series panels wit...

Страница 3: ...o short side of the panel 12 Fig 7 Clamping of REC Alpha Pure R Series panels with rails parallel to long side of the panel 13 Fig 8 Clamping of REC Alpha Pure R Series panels using short rails 14 Fig...

Страница 4: ...nly qualified personnel must perform work on photovoltaic systems such as installation commissioning maintenance and repairs Be sure to follow the safety instructions for all system components Ensurin...

Страница 5: ...served during handling to avoid the risk of sparking fire hazards burns and lethal electric shocks Exercise extreme caution when wiring panels and look out for damaged or dirty cables etc Never insert...

Страница 6: ...rdegradationtothepackagingorpanelcomponents pallets and panels must be stored in a controlled environment ideally internal where it is protected from the elements e g rain dust and direct sunlight If...

Страница 7: ...age Voc and short circuit current Isc deviate from specification this may indicate a configuration fault Correct DC polarity must be observed at all times Electrical Ratings Electricalratingsarewithin...

Страница 8: ...o the manufacturer s instructions including specific hardware and torque requirements Ensure the clamps used are suitable for the planned installation and expected system design loads The grip area mu...

Страница 9: ...Pa 2400Pa 2400Pa 1600Pa 1600Pa X 255 375 mm 1800Pa 1800Pa 1200Pa 1200Pa 4200Pa 2400Pa 2800Pa 1600Pa 5400Pa 2400Pa 3600Pa 1600Pa X 375 505 mm 1800Pa 1800Pa 1200Pa 1200Pa 6200Pa 4000Pa 4133Pa 2666Pa 700...

Страница 10: ...PANELS WITH CONTINOUS RAILS PARALLEL TO LONG SIDE OF THE PANEL A continous rail or other support structure spans the complete underside of the panel Legend Clearance Gap Clamping zone 20 40 mm 40 60 m...

Страница 11: ...2400Pa 3000Pa 1600Pa X 375 505 mm 1200Pa 1200Pa 800Pa 800Pa 3000Pa 3000Pa 2000Pa 2000Pa 4200Pa 4000Pa 2800Pa 2666Pa X 505 610 mm 1200Pa 1200Pa 800Pa 800Pa 2400Pa 2400Pa 1600Pa 1600Pa 3600Pa 2400Pa 240...

Страница 12: ...800Pa 1800Pa 1200Pa 1200Pa 6200Pa 3000Pa 4133Pa 2000Pa 7000Pa 3000Pa 4666Pa 2000Pa 520 570 mm 1200Pa 1200Pa 800Pa 800Pa 3000Pa 2400Pa 2000Pa 1600Pa 5400Pa 2400Pa 3600Pa 1600Pa 570 730 mm 2400Pa 2400Pa...

Страница 13: ...other support structure spans the complete underside of the panel Legend Clearance Gap Clamping zone 20 40 mm 40 60 mm 60 mm Test Load DesignLoad Test Load DesignLoad Test Load DesignLoad 90 730 mm 1...

Страница 14: ...0Pa 800Pa 2400Pa 2400Pa 1600Pa 1600Pa 3600Pa 2400Pa 2400Pa 1600Pa 570 730 mm 1200Pa 1200Pa 800Pa 800Pa 1600Pa 1600Pa 1066Pa 1066Pa 2400Pa 2400Pa 1600Pa 1600Pa 0 200 mm X 800Pa 800Pa 533Pa 533Pa 800Pa...

Страница 15: ...apply a safety factor of 1 5 to the stated test load e g test load 5400 Pa 1 5 3600 Pa design load Part Name Material Rail 6105 T5 aluminum extrusion Bolt M6 x 25 drop inT stud kit Nut M6 flanged hex...

Страница 16: ...pport structures must be used to secure the panel The center point of each clamp and the minimum grip length must be fully located within the marked zone to be rated to the given value fig 12 Legend C...

Страница 17: ...used to secure the panel The center point of each clamp and the minimum grip length must be fully located within the marked zone to be rated to the given value fig 13 Legend Clearance Gap Clamping zo...

Страница 18: ...t side as shown in fig 12 and can be further identified by the grounding symbol stamped in the frame next to it Check all applicable requirements before beginning installation Suitable grounding clips...

Страница 19: ...coveranyfaulttraceabletothereplacedconnectors Anyothermodificationtothepanelisprohibited includingthe openingofthejunctionbox unlessexplicitlyauthorizedbyREC Doingsowillinvalidatethewarranty CABLEMANA...

Страница 20: ...ng to local guidelines and regulations By ensuring REC solar panels are disposed of correctly you will help prevent any negative impact on the environment and human health The majority of the panel co...

Страница 21: ...0 04 C The temperature coefficients stated are linear values CERTIFICATIONS IEC 61215 2016 IEC 61730 2016 UL 61730 IEC 62804 PID IEC 61701 Salt Mist IEC 62716 Ammonia Resistance ISO 11925 2 Ignitabili...

Страница 22: ...IMUM RATINGS Operational temperature 40 85 C System voltage 1000V Test load front 7000Pa 713 kg m Test load rear 3000Pa 305 kg m Series fuse rating 25A Reverse current 25A See installation manual for...

Страница 23: ...slack to prevent damage due to water level changes and wave motions ii Mounting panels Installation of REC solar panels must be in accordance with the aforementioned standard mounting instructions Th...

Страница 24: ...n MLPE device directly to the solar panel frame follow the MLPE manufacturer s instructions to ensure optimum mounting of the device and prevent any slippage during operation WheninstallinganMLPEdevic...

Страница 25: ...of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits The technical documentation and full compliance...

Страница 26: ...tage limits The technical documentation and full compliance with the standards listed below proves the conformity of the product with the requirements of and conformity with the Electrical Equipment S...

Страница 27: ...ddition of REC Alpha 72 Series 03 2021 6 Updated Datasheets 06 2021 7 Addition of REC Alpha Pure Series 11 2021 8 Updated Datasheets 03 2022 9 Added six point clamping and added requirement for washer...

Страница 28: ...RECSOLARPTE LTD 20TUASSOUTHAVENUE14 SINGAPORE637312 SINGAPORE Tel 6564959228 Mail post recgroup com www recgroup com...

Отзывы: