![Real Flame CAPTIVA Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/real-flame/captiva/captiva_installation-and-operating-manual_1425070004.webp)
MODEL
CAPTIVA 600
SERIAL NO.
DATE OF MANUFACTURE
GAS TYPE
APPROVAL: GSCS20081
NATURAL GAS @ 1.00 kPa Test Pressure Point (High)
Injector Size
Gas Consumption
1.65 mm
26 Mj/hr
LPG @ 2.65 kPa Test Pressure Point (High)
Injector Size
Gas Consumption
1.00 mm
26 Mj/hr
NATURAL GAS @ .40 kPa Test Pressure Point (Low)
Injector Size
Gas Consumption
1.65 mm
15 Mj/hr
LPG @ 0.95 kPa Test Pressure Point (Low)
Injector Size
Gas Consumption
1.00 mm
15 Mj/hr
MODEL
CAPTIVA 900
SERIAL NO.
DATE OF MANUFACTURE
GAS TYPE
APPROVAL: GSCS20081
NATURAL GAS @ 1.00 kPa Test Pressure Point (High)
Injector Size
Gas Consumption
1.85 mm
30 Mj/hr
LPG @ 2.65 kPa Test Pressure Point (High)
Injector Size
Gas Consumption
1.1 mm
30 Mj/hr
NATURAL GAS @ .40 kPa Test Pressure Point (Low)
Injector Size
Gas Consumption
1.85 mm
19 Mj/hr
LPG @ 1.00 kPa Test Pressure Point (Low)
Injector Size
Gas Consumption
1.1 mm
18 Mj/hr
4
DATA PLATE
(Affixed to the base of the unit for reference to gas pressure & consumption)