![Real Flame CAPTIVA Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/real-flame/captiva/captiva_installation-and-operating-manual_1425070013.webp)
13
After carrying out service or
replacing parts, reverse the
above processes to reinstate
the components.
Prior to lighting ensure there
are no gas leaks.
Figure (15) To remove the fan undo the wing
nuts on each side of the fan. the fan can then
be removed. to get the fan out the remote box
must be removed and the burner tube is to be
undone at the bulkhead.
Figure (14) Remove the burner to be nut
either from the bulkhead or the brass elbow.
the valve can then be removed.
Figure (13) Loosen the wing nuts of each side
of the valve which will allow the valve to slide
out.
Figure (12) Undo the two screws at the front
of the module, then remove the wiring
harness, the module can then be removed.
SERVICING AND MAINTENANCE
(continued)