CHIMNEY CONNECTOR
(also known as “flue pipe” or “stove pipe”). The chimney connector joins the
stove to the chimney. It should be 6” inches in diameter, carbon steel, 24-gauge minimum.
THIMBLE
. A manufactured or site-constructed device installed in combustible walls through which the
chimney connector passes to the chimney. It is intended
to keep
walls from igniting.
CHIMNEY.
[See specifications on Pages 8-10.] APPROVED MASONRY with at least 5/8” fire clay
lining joined with refractory cement or other listed lining system suitable for use with coal stoves, or
PREFABRICATED 6- or 8-inch listed high temperature* residential type and building heating appli-
ance chimney. Components required by manufacturers for installation such as the chimney support
base, firestop (as appropriate), attic insulation shield, insulated tee, etc., are necessary to assure a
safe chimney installation. Use only components manufactured for the chimney.
FLOOR PROTECTOR.
1l4” Mineral board or equivalent. Measurements: 8” beyond the sides and
back; 18” beyond the front. Total Dimensions: 40” x 45” or larger.
Avoid Fire
Maintain the designated clearance distance to combustibles. Insulation must not touch the
chimney. There must be the designated air space clearance around the chimney. This air
space around a chimney is necessary to allow natural heat removal from the area. Insulation
in this space will cause a heat build-up which may ignite wood framing.
SAFETY NOTICE
This stove is not properly installed, a house fire may result. For your safety, follow the instal-
lation directions. Contact your local building or fire official about restrictions and installation
inspection requirements in your area. Check your local building code.
Please read this entire manual before you install and use your new stove. Failure to
follow instructions may result in property damage, bodily injury, or even death.
SAFETY NOTICE
III. Installation