![Reach Technology PoE4N/10G Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/reach-technology/poe4n-10g/poe4n-10g_manual_1424858008.webp)
Reach PoE4N/10G Tester Manual 1.1
06/15/2020
Page 8
3.3.
UUT Connections
The RT-PoE4N/10G has 24 test ports, configured as 12 pairs (1-2, 3-4, 5-6, etc.). Each
port has the ability to act as a PD load to the UUT. In addition, each port pair can be
configured to pass data from one port to the other via internal straight through
connections, allowing the loads to be applied while passing traffic. All data path
connections are made via signal relays and 100 ohm differential pairs for data integrity.
Connect the port of the PoE supplying device under test to the UUT connector via a
standard straight through Ethernet connector (see the
information regarding cables). There is an 802.3at class transformer isolating the UUT
ports in each port pair so that power can be tapped from the UUT (see the
section for more details).
Note that the devices connected to any given port pair cannot "see" the power from the
other port. In other words, the UUT ports in a port pair are connected from a data
perspective, and each UUT port connects to the RT-PoE4N/10G active load from a power
(PoE) perspective.
NOTE: with high power loads, the DC balance of the patch cables used is important to
avoid DC saturation of the Ethernet transformers. DC Balance (DC resistance per side
of the power carrying pair) should be within 3%. The standard patch cable
specifications of Cat 5, 5e, and 6 do not specify DC balance.