9/13 

ƒ

 

E.M.D. (Micrometrical Electronic Movement) 

If necessary, you can move the line or edge to follow from ±0,1 to ±14 millimetres, from the position 

indicated by the laser.  

 

 

Simply press the 

right arrow

 for a positive movement, 

 

or the 

left arrow

 for a negative movement.  

 

 

Once a certain movement value is exceeded (±50% ca. of the viewing area set), the laser indicator 
will start flashing.  

 

The movement value will be reset automatically when you access the change the viewing area 
function. 

 

Attention!

 When the line reading mode is selected, the E.M.D. function is blocked each time that the 

LED that signals the lack of the index line is active (LED on). 

 

ƒ

 

INTERRUPTED LINE FUNCTION

You can activate the interrupted line function so that when the print is not present, the belt guide does 
not perform any adjustment, but it remains in stand-by until the line appears again. This option is 

available only if the line reading has been selected.  

 

To activate this function keep the 

calibration/contrast 

and the

 left arrow 

keys pressed 

at the same time. The line reading LED will start flashing, indicating that the function 
is active.  

 

 

To disable the function keep the 

calibration/contrast 

and the

 right arrow 

keys pressed 

at the same time. 

 

 

Attention!

 If this function is active, the wait time of the belt guide system must not be set (infinite wait 

time) and the Work Zone of the belt guide must be less than 100. 

 

ƒ

 

SW VERSION

:

 

Press the 

calibration/contrast 

and

 line/edge

 keys contemporaneously to display the 

Sw version of the TL01-A. 

 

 

 

 

Содержание TL01-A

Страница 1: ...ENG TL01 A Optical sensor USER S MANUAL...

Страница 2: ......

Страница 3: ...2 TL01 A sensor functioning 3 Positioning the TL01 A sensor 4 Positioning the TL01 A sensor with contrast lamp 6 Quick start up 7 Electrical characteristics 10 Other characteristics 10 Optional 10 TL...

Страница 4: ...pted in the member state in which it was installed WEEE Waste Electrical and Electronic Equipment may be intended for individual collective or mixed collection and recovery systems at designated centr...

Страница 5: ...d changes Immediate display of the reading area with the Laser pointer Simple and quick calibration in just a few seconds Automatic selection of the illumination colour for maximum contrast the sensor...

Страница 6: ...aptured contrast Field of view If the contrast is placed as shown in this diagram during the calibration the sensor will indicate the position of the first contrast dark light found by scan from left...

Страница 7: ...upon request for 1 bars 25 4mm material The spacer useful to find the correct angle of the TL01 A in relation to the roller must be positioned between the sensor and the roller making sure that the ho...

Страница 8: ...Re S p A TL01 A 03 07 12 5 13 In relation to the material angle the TL01 A sensor can be positioned as follows 70 5 7 0 5...

Страница 9: ...Re S p A TL01 A 03 07 12 6 13 Positioning the TL01 A sensor with contrast lamp 70 5 64 8 37 5 45 50 29 5 8 7 20 61 50 80 20 transparent zone...

Страница 10: ...an be used to perform the calibration Focus 1 2 The display will show a numerical value Move the sensor closer or further away from the material in order to achieve the maximum reflection value The va...

Страница 11: ...ontemporaneously 2 the field of view expressed in mm will appear on the display as a number 3 press the right arrow to increase the field of view or press the left arrow to reduce it 4 once the desire...

Страница 12: ...NTERRUPTED LINE FUNCTION You can activate the interrupted line function so that when the print is not present the belt guide does not perform any adjustment but it remains in stand by until the line a...

Страница 13: ...L x P x H Response time 1msec Working temperature range 0 60 C Degree of protection IP40 Inversion of the reading direction without recalibrating the system Focus procedure to be performed only once...

Страница 14: ...gnal White 12 24Vdc Black 0Vdc Blue 0 5Vdc analog output Brown LIN signal NC Pin connector Wires colour Signal 1 Blue 0 5Vdc analog output 2 Black 0Vdc 3 White 12 24Vdc 4 Brown LIN signal 1 2 3 4 L ma...

Страница 15: ...dge Position the sensor or the material so that the line edge is inside the sensor s field of view The E M D function is not working the red LED is off The electronic movement is at the maximum NOTE i...

Страница 16: ...guarantee includes spare parts and labour It does not include shipment costs for device delivery or recall The guarantee is invalidated by improper use of the device incorrect installation faulty elec...

Страница 17: ...linea contrasto per messa a fuoco This page can be used to perform the focus procedure by using the black line printed as contrast to read...

Страница 18: ......

Страница 19: ...This page can be used to perform the focus procedure by using the black line printed as contrast to read...

Страница 20: ...dustriali Via Firenze 3 20060 BUSSERO MI ITALY Fax 39 02 95 03 89 86 Technical support Tel 39 02 95 24 30 300 E mail support re spa com Sales support Tel 39 02 95 24 30 200 E mail sales re spa com www...

Отзывы: