3.
If the contrast lamp is used, press the
right arrow
during the focus in order to disable the internal
lamps of TL01-A. (use the
left arrow
to activate them)
4.
Remove the sheet, if it was used to perform the contrast procedure. Position the line or edge to
follow on the luminous spot:
Calibration
Other functions
VIEWING AREA
:
The default viewing area of the TL01-A is 5mm.
You can change the field of view of the sensor by a minimum of 1mm and a maximum of 28mm:
1.
press the
right
and
left arrows
contemporaneously;
2.
the field of view, expressed in mm, will appear on the display as a number;
3.
press the
right arrow
to increase the field of view,
or press the
left arrow
to reduce it;
4.
once the desired value has been set, press the
line/edge
key
.
READING DIRECTION
:
To change the reading direction, press the
line/edge
key pressed for about 3÷4 seconds, until
the arrow indicating the reading direction lights up.
EDGE OR LINE
:
To select whether to read line or edge, press the
line/edge
key briefly. The LED for the type of
reading selected, will light up automatically.
Line:
Edge:
Line to follow
Edge to follow
Press the
calibration/contrast
key briefly. The sensor will automatically select the best lamp colour
for the application.