RDC5121 Control System Manual
SHENZHEN RUIDA TECHNOLOGY
19
4.3.4 Set Fact Para
After the
“
Set Fact Para
”
is selected and the Enter key pressed, the interface will show the specific
password to be entered when set as default parameter.
Push
“
X+/-
”
keys and
“
Y+/-
”
keys to select the characters, and push the
“
Enter
”
key to valid the
characters, when finishing enter the password ,that is to say, the six characters, if the password is error, it
prompts there is some error, or, all parameters are stored.
After the manufacturer regulates all parameters of the machine
well (including all manufacturer parameters and user parameters),
this function can be used to store the well-regulated parameters to
help users to recover the original parameters (including all
manufacturer parameters and user parameters) through selecting
“Recover Para” when they regulate parameters improperly.
4.3.5 Recovery as Fact Para
After the
“
Recovery as Fact Para
”
is selected and the Enter key pressed, the
“
Successful Recovery
”
dialog box will pop up to prompt that all manufacturer parameters and user parameters are recovered
successfully. You can return to the previous menu by press the Enter key.
4.3.6 Origin Setup+
When the cursor is on this item, push the “Enter” key to show as below:
Figure 4.13
Prompt