background image

 

 

 

                                                                                  

Product Guide | Issue 1.5 | GP Gateway

  

Page

 

11

 

 

Contacts 

The GP Gateway 

 

 

7

 

Contact Details 

 

RCS Energy Management  

30 Kingfisher Court

 

Hambridge Road 
Newbury 
Berkshire 
RG14 5SJ 
UNITED KINGDOM 
 
Tel:  +44 (0) 1635 231600 
Fax: +44 (0) 1635 231699 
Email: 

[email protected]

 

 
Website: 

www.rcsenergymanagement.co.uk

 

 

RCS Energy Management is a trading name of Maxey Moverley Ltd.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание SM1020

Страница 1: ...way s Page 1 Product Guide Issue 1 5 The SM1020 GP Gateway s Page 1 Product Guide Issue 1 5 The SM1020 GP Gateway s Page 1 Product Guide SM1020 GP Gateway SM1020 W GP Gateway Product Guide Issue 1 5 G...

Страница 2: ...mation 4 2 SETTING UP THE GATEWAY 5 2 1 User Instructions 5 2 2 Screen Shot of the Configuration Page 5 3 CONFIGURATION 6 3 1 Units 6 3 2 Network Parameters 6 3 3 XML Parameters 6 3 4 Adaptor Control...

Страница 3: ...arameter management Communicate with 32 RS485 Devices View real time controller status information The SM1020 W version supports the following Williams LAE controller types AD2 5 AD3 5 WUMC2 WUMC3 WUB...

Страница 4: ...present RS485 Status LED Red This indicator will initially be off until valid communication activity is detected Once RS485 communication activity is present the LED will flash at an intermittent rate...

Страница 5: ...et port of the GP Gateway 2 Connect the CAT5 patch lead into the Ethernet port of the laptop PC which will be used to configure the GP Gateway 3 Ensure that the laptop PC is assigned a static IP addre...

Страница 6: ...commence after a period of 2 minutes following a restart 3 2 Network Parameters To assign the GP Gateway a static IP address simply click into the desired field and type the required address If the us...

Страница 7: ...2A DC 5V 5 0 5A EMC EN 55014 1 2006 A2 Weight 65 Grams Excluding PSU Size 110mm L x 57mm W x 26mm D Inclusive of mounting flanges Ventilation No requirement for forced air cooling Operating temperatu...

Страница 8: ...teway 4 2 Ordering Information Part Number Product Name Description SM1020 GP Gateway General Purpose RS485 to IP Protocol Converter SM1020 W GP Gateway for use with Williams refrigeration units Gener...

Страница 9: ...nts First Draft 02 02 2013 DS First Draft Issued for internal review Issue 1 0 17 06 2013 DS Agreed content format Issued for customer distribution Issue 1 1 28 06 2013 DS Image alteration Issued for...

Страница 10: ...improvements the information contained within this document is subject to change at any time without prior notice RCS Energy Management shall not be liable for any errors or omissions for incidental...

Страница 11: ...ls RCS Energy Management 30 Kingfisher Court Hambridge Road Newbury Berkshire RG14 5SJ UNITED KINGDOM Tel 44 0 1635 231600 Fax 44 0 1635 231699 Email sales rcsenergymanagement co uk Website www rcsene...

Страница 12: ...ogether Using an RS 485 compliant transmitter with twisted pair wire reduces two major sources of problems for designers of high speed long distance networks radiated EMI and received EMI RCS suggest...