3.1.3 Order of item maintenance
3.1.3.1 Sensor maintenance
Complete dismantling of sensor must be performed in the following
consequence (fig. 3.1):
-
to disconnect interface and connecting cable;
-
to unscrew and remove measuring head, after that to unscrew sensor probe
from the flange;
-
to close an aperture of flange with socket plug IEC EN C. 100 (see Table 1.3),
as shown in fig. 3.1;
Fig. 3.1 Complete dismantling of fuel level sensor and installing socket plug
-
to wash entire part of probe with fuel (with which the sensor is
opertated) and to blow with compressed air;
-
to control own parameters of the measuring head (using "eS Install"
software, according to procedure, described in appendix А of the
document "EN.000 ИМ. Installation manual ");
-
to perform installation and sealing of the sensor according to
requirements 1.1.5.2.
3.1.3.2 Maintenance of Spark Protection Module
Maintenance of spark protection module consists in its examination and
elimination of violations during the operation.
During examination it is necessary to perform the following operations:
-
to inspect the case and to identify mechanical damage;
-
to clean the case of spark protection module from dust and dirt;
-
to check labeling;
-
to check the attachment of module;