BA-2120/2240 CP
4
FRONT PANEL CONTROLS
VORDERSEITE
1. POWER SWITCH
Power this switch "ON" will make the power and supply the
power.
2. LED INDICATORS
- TEMPERATURE (RED COLOR).
If the temperature of heat-sink is 100°C more, red color of
LED indicator will be flashed.
- PROTECTION (RED COLOR)
- NORMAL:
When power "ON/OFF". Red color LED indicator will be
disappear after two or three seconds.
- ABNORMAL:
1. Continuous- Under over temperature
2. Repeat ligthing On/Off- Speaker line shorten
- POWER (YELLOW COLOR)
When power "ON" makes yellow color.
- PRIORITY (RED COLOR)
When priority control is activated, PGM audio signal is
closed and Priority audio signal of priority will be come-
out.
3. OUT LEVEL METER
This is LED LEVEL meter. Adjust volume before clip LED
"TURN ON".
4. PGM LEVEL VOLUME
This is volume control adjusting output level of amplifier for
PGM audio input.
1. EIN- /AUSSCHALTER
Nach Betätigen dieses Schalters ist das Gerät betriebs-
bereit.
2. LED`s
- TEMPERATUR LED (Rot).
Bei Überhitzung des Verstärkers (über 100°C am Kühlkörper)
leuchtet diese LED.
- PROTECT LED (Rot)
- Normal Betrieb:
Ca. 2 - 3 s nach Einschalten des Verstärkers erlischt die LED.
- Störung:
1. Ständiges Leuchten zeigt Temperatur Warnung an.
2. Ständiges Aufleuchten zeigt Kurzschluß der Lautspre-
cherlinie an.
- POWER (Gelb)
Diese LED leuchtet bei eingeschaltetem Gerät.
- PRIORITY (Rot)
Wenn der Verstärker im Prioritätsbetrieb läuft leuchtet
diese LED.
3. LEVEL METER
LED Level Meter als Anzeige des Signalpegels, wobei die
CLIP LED leuchtet, wenn die Ausgangsspannung über-
steuert wird.
4. LAUTSTÄRKEREGLER
Dieser Regler bestimmt die Lautstärke des Programms nicht
aber die Lautstärke des Prioritätsignals.
Содержание BA-2120 CP
Страница 1: ...BA 2120 2240 CP...
Страница 7: ...BA 2120 2240 CP 7...
Страница 8: ...BA 2120 2240 CP 8 BLOCK DIAGRAM...
Страница 10: ...BA 2120 2240 CP 10 Note...