background image

 
R-FORCE FOR INNER DOORS – INSTALLING AND OPERATING 

PROGRAMMING THE UNIT 

 

 

 

Programming the unit 

General information 

In order to program the unit, it must be set to programming mode by entering the 

system 

code. The default system code is 1234. 

Recommendation: Change the default system code to your own code as soon as 
possible.  (See ”Changing the system code” on page 12.) 

After entering the system code, you select a menu, depending on what you want to do.  

Access codes can consist of three to six numbers.  

The unit’s LED lamp can help during programming because it shows which step you are at. 
The following symbols are used in the instructions to show what the lamp is doing 

after 

each described step: 

Off  

(operating mode) 

Steady shine 

(programming mode) 

Slow flashing  

(menu selected)  

Fast flashing 

(waiting for input) 

 

 

       

 

See also ”Appendix 1: Signals in R-FORCE” on page 17. 

Programming mode terminates automatically after about 20 seconds of inaction. It 
can also be exited manually by pressing  0 and then #.  

Menu quick guide 

Menu no.  Used for 

Page 

Adding entry codes that unlock the door 

10 

Changing the system code 

12 

Entering a code for activating and deactivating access code 

13 

Deleting codes 

10 

5, 1 

Activating or deactivating beep when opening 

11 

5, 2 

Activating or deactivating the battery warning sound 

12 

Adjusting how long the lock stays open 

11 

Master reset 

14 

!

 

!

 

Содержание R-FORCE

Страница 1: ...08 546 560 00 info rco se www rco se 2020 RCO Security AB All rights reserved November 2020 R FORCE for inner doors Installing and operating Describes how to mount program and troubleshoot the code l...

Страница 2: ...g entry codes that unlock the door 10 Deleting codes 10 Activating or deactivating beep when opening 11 Adjusting how long the lock stays open 11 Activating or deactivating the battery warning sound 1...

Страница 3: ...d The CE marking is on the back of each unit The marking is repeated on the inside of the unit s battery cover Environment The environmental declaration is available at www rco se Batteries Spent batt...

Страница 4: ...d cylinder rings Otherwise everything that is needed for mounting is included in the box Batteries are not included Compatible door locks Some of the most common locks that R FORCE works with ASSA mod...

Страница 5: ...he surface of the door must not be so uneven that R FORCE becomes deformed during mounting For security the gap between the door blade and the door frame should be as small as possible Change the defa...

Страница 6: ...the two steel bolt extenders 1 and the washers 14 on the cylinder 2 Mount the cylinder and the cylinder extender 3 in the lock If the cylinder extender is too long the key will be difficult to turn In...

Страница 7: ...r 4 9 Gently tighten the retainer bolts 10 10 Connect the red battery wire to one battery the black wire to the other and insert the batteries Only use alkaline batteries of type 6LR61 9V 550 mAh 11 M...

Страница 8: ...inserted Programmed codes will not be lost What can happen is that the buzzer sounds constantly or that the codes do not work 1 Remove both batteries 2 Press six numbers in succession to reset the bat...

Страница 9: ...at The following symbols are used in the instructions to show what the lamp is doing after each described step Off operating mode Steady shine programming mode Slow flashing menu selected Fast flashin...

Страница 10: ...ry position Confirm with 4 Enter the desired code 3 6 digits Confirm with A beep confirms the change 5 To add more codes repeat steps 3 and 4 6 To exit menu 1 press 0 Select a new menu and press Or to...

Страница 11: ...ction then 3 Press 1 submenu then 4 Press 1 to activate sound Or press 0 to deactivate it Confirm with A beep confirms the change 5 To exit press 0 then Adjusting how long the lock stays open You can...

Страница 12: ...ote The system code cannot be the same as any of the access codes If the system code has more digits than a code but uses the same initial digits then subsequent digits must be entered within 2 second...

Страница 13: ...itself will not open the door It s zero 0 that opens the door 1 Set the unit to programming mode by entering the system code 2 Press 3 menu selection then 3 Enter the desired code 3 6 digits Confirm...

Страница 14: ...code 2 Press 9 menu selection then 3 Press 1 to confirm master reset Confirm again with A beep confirms the reset If the system code is not known If the system code has been lost the below procedure i...

Страница 15: ...fy that R FORCE is correctly mounted parallel with the edge of the door and perpendicular to the door surface right angles to the lever shaft R FORCE should also be mounted with two screws 20 in the b...

Страница 16: ...is working but beeps three times when an access code is entered This is the battery warning Change the batteries See Changing the batteries on page 8 The buzzer sounds constantly or no codes are worki...

Страница 17: ...s code entered Steady shine Programming mode Or valid access code entered door unlocked Slow flashing A menu was selected waiting for you to select a submenu or enter a new value for example a memory...

Страница 18: ...5 V Current consumption Idle 14 18 mA Programming mode 1000 mA Activation pulse 559 mA Deactivation pulse 380 mA Battery life of fresh batteries 100 accesses 24h 34 months 50 accesses 24h 40 months S...

Страница 19: ...CE FOR INNER DOORS INSTALLING AND OPERATING CONFIGURED CODES 19 Configured codes Code position Description Code 1 2 3 4 5 6 7 8 9 Code for activating and deactivating access code 0 see page 13 System...

Отзывы: