11. Remove the bolts securing the large ECU plate on the left side of the ECU cabinet as shown in Figure 11, “Access
to the Rear of the ECU Cabinet,” and move the ECU to allow access to the back wall of the ECU Cabinet.
FIGURE 11. Access to the Rear of the ECU Cabinet
N OTE:
Do not discard or modify the ECU or mounting plate.
12. Use a 1- 1/ 2” hole saw to drill a hole through the back of the ECU cabinet for the bulkhead connection of the
RCM - Sprayer bulkhead cable (P/ N 115- 2005- 018) to pass through.
The recommended location for this port is toward the left edge of the box behind and below the ECU bracket
just removed, about 1.0” below the bracket and 2.5” from the left edge of the ECU cabinet as shown in Figure 12
on page 21.
N OTE:
Be careful not to damage any existing electrical components or wiring while drilling. This hole will be
used later to connect the chassis cable to the electrical box cabling for final system connections.
Remove
Bolts