3
Install the RCM - Sprayer: RCM - Sprayer Installation
17
IN STALL THE RCM - SPRAYER
ECU CABINET PREPARATION
1. Locate the ECU Cabinet on the right side of the machine between the axles and remove the cover.
FIGURE 6. RoGator 1300 ECU Cabinet Location
2. Locate the Raven ISO Product Control ECU.
3. Use a socket and socket extension to loosen the bolt securing the ECU mounting plate to the rear cabinet wall
and remove the plate from the ECU cabinet.
FIGURE 7. ECU M ounting Plate
M achine ECU
Cabinet
Raven ISO Product Controller ECU