RCF HDL 50-A Скачать руководство пользователя страница 3

IMPORTANT NOTE

 

Before connecting using or rigging the system, please read this 
instruction manual carefully and keep it on hand for future reference. 
The manual is to be considered an integral part of the product 
and must accompany the system when it changes ownership as a 
reference for correct installation and use as well as for the safety 
precautions. RCF S.p.A. will not assume any responsibility for the 
incorrect installation and/or use of the product. 

WARNING 

• To prevent the risk of fire or electric shock, never expose 
this equipment to rain or humidity.

• The system TT+ line arrays should be rigged and flown by 

professional riggers or trained personnel under professional riggers’ 
supervision.

• Before rigging the system carefully read this manual. 

2. GENERAL 

SAFETY 

INSTRUCTION 

AND WARNINGS

SAFETY PRECAUTIONS 

1. 

All the precautions, in particular the safety ones, must be read with special attention, as they provide important information.

2. 

Power supply from mains

The mains voltage is sufficiently high to involve a risk of electrocution; install and connect this product before plugging it in.
Before powering up, make sure that all the connections have been made correctly and the voltage of your mains corresponds to 
the voltage shown on the rating plate on the unit, if not, please contact your RCF dealer.
The metallic parts of the unit are earthed through the power cable. An apparatus with CLASS I construction shall be connected 
to a mains socket outlet with a protective earthing connection.
Protect the power cable from damage; make sure it is positioned in a way that it cannot be stepped on or crushed by objects.
To prevent the risk of electric shock, never open this product: there are no parts inside that the user needs to access.

3. 

Make sure that no objects or liquids can get into this product, as this may cause a short circuit.

This apparatus shall not be exposed to dripping or splashing. No objects filled with liquid, such as vases, shall be placed on this 
apparatus. No naked sources (such as lighted candles) should be placed on this apparatus.

4. 

Never attempt to carry out any operations, modifications or repairs that are not expressly described in this manual.

Contact your authorized service centre or qualified personnel should any of the following occur:

- the product does not function (or functions in an anomalous way).
- The power cable has been damaged.
- Objects or liquids have got in the unit.
- The product has been subject to a heavy impact.

5. 

If this product is not used for a long period, disconnect the power cable.

6.

 If this product begins emitting any strange odours or smoke, switch it off immediately and disconnect the power cable.

7. 

Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang this product by using elements that 
are unsuitable or not specific for this purpose. Also check the suitability of the support surface to which the product is anchored 

Содержание HDL 50-A

Страница 1: ...OWNER MANUAL ACTIVE THREE WAY LINE ARRAY MODULE HDL 50 A...

Страница 2: ...pressure levels constant directivity and sound quality other aspects are important for rental and production companies such as reduced weight and ease of use to optimize transport and rigging time HD...

Страница 3: ...th CLASS I construction shall be connected to a mains socket outlet with a protective earthing connection Protect the power cable from damage make sure it is positioned in a way that it cannot be step...

Страница 4: ...ipment support trolley assembly must be moved with extreme caution Sudden stops excessive pushing force and uneven floors may cause the assembly to overturn 10 There are numerous mechanical and electr...

Страница 5: ...y low weight for easy handling and flying 4 POWER REQUIREMENTS AND SET UP WARNING The system is designed to operate in hostile and demanding situations Nevertheless it is important to take extremely c...

Страница 6: ...h Country and local laws and regulations Always check that all the parts of the rigging system that are not provided from RCF are appropriate for the application approved certified and marked properly...

Страница 7: ...arp break at a stress below the ultimate strength At this critical stress the material elongates considerably with no apparent change in stress The stress at which this occurs is referred to as theYie...

Страница 8: ...n compression and the rear links are supporting the total weight of the system plus the front compression Always check very carefully with the HDL 50 A Shape Designer software all this kind of situati...

Страница 9: ...he following version of the software the user can directly download the application without the Runtime Two versions 32 bit and 64 bit are available for the download IMPORTANT Matlab no longer support...

Страница 10: ......

Страница 11: ...After the choice of folders for HDL50 SahpeDesigner software Figure 2 and Matlab Libraries Runtime the installer takes a couple of minutes for the installation procedure...

Страница 12: ...flybar as shown in the picture below After entering all the data input in the left part of the user interface by pressing the AUTOSPLAY button the software will perform Hanging point for the shackle...

Страница 13: ...above it is necessary to reduce in the global equalization the level of the low frequencies progressively reducing the gain if the frequency decreases low shelf filter The HDL50 Shape Designer softwa...

Страница 14: ...mpensation should be translated in terms of decibels that should be progressively added with the increase of high frequencies It is important to note that the formula gives an absorption that exponent...

Страница 15: ...of the preset loaded in the cabinet the number is shown besides the drawing HIGH FREQUENCY PRESET USING REAR PANEL ROTARY KNOB From RDNet the user can have access to all the fifteen presets but using...

Страница 16: ...AR PICK UP TTL 55 A Hooking bracket and shakle for safety chain 13360127 4 Mount bracket inclinometer 5 QUICK LOCK PINS KIT 4F Pin for hooking to the front bracket 13360332 6 QUICK LOCK PINS KIT 8R Pi...

Страница 17: ...f the array when it is suspended from a single pick up point 2 13360127 FLY BAR PICK UP TTL 55 A 3 13360351 AC 2X AZIMUT PLATE It allows the horizontal aim control of the cluster The system must be ho...

Страница 18: ...r links in conjunction with the front and rear rigging strands of the loudspeaker cabinets and the Flying frame Ensure all Locking pins are fully inserted and securely locked before lifting any load I...

Страница 19: ...ocked by briefly pulling the Locking pin towards you SINGLE PICKPOINT OPERATION suggested for 8 modules maximum Fit the pickup in the proper position number suggested by HDL 50 A Shape Designer and fi...

Страница 20: ...based on HDL 50A Shape Designer software RIGGING THE FLYBAR TO THE SPEAKERS Move the kart with the first 4 modules under the flybar Attach the flybar onto the first cabinet of the assembly until the f...

Страница 21: ...traction on the first module insert the locking pin in the hole B Always follow the sequence suspension and locking and never use only the locking pin because it is not designed to load the weight of...

Страница 22: ...rved systems Pull out the front and rear pin from the cart and remove it Remove all locking pins of the second cart cabinets and preset the splay angles of all cabinets based on HDL 50A Shape Designer...

Страница 23: ...e procedure of the last 4 module for all of the following modules Warning Although with a single pick up point is possible to compose a cluster modules 20 it is highly discuraged to use a single pick...

Страница 24: ...t A of the flybar using the quick lock pins of the flybar Secure the front brackets by compression Turn the rear stacking bracket of the flybar and select the proper angle The correspondence of the br...

Страница 25: ...he two quick lock pins On subs 9006 and 9007 series fix the optional accessory Ac Connecting Plate cod 13360231 to M20 female screw on the upper part of the sub Place the flybar to sub and insert theA...

Страница 26: ...treatment the rigging components are temporarily protected against moisture However ensure the components are in a dry state while stored or during transportation and use SAFETY GUIDE LINES HDL50 A K...

Страница 27: ...itivity 4 dBu PROCESSOR Crossover Frequency 200 800 Hz Protections thermal RMS Limiter soft limiter Controls Cluster size HF air correction AMPLIFIER Total Power 4400 W Peak High Frequencies 1100 W Pe...

Страница 28: ...www rcf it 10307486 Rev A RCF SpA Via Raffaello 13 42124 Reggio Emilia Italy tel 39 0522 274411 fax 39 0522 274484 e mail rcfservice rcf it...

Отзывы: