NOTES FOR INSTALLATION
The ED series amplifiers are designed to be housed in 19” racks / flight-cases (height: 2 units). If
installation is made inside a rack enclosure, we recommend you to use the attachment fittings on
the back of the amplifier, so the front panel does not have to support the entire unit weight. Make
sure there is sufficient ventilation for the amplifier to be cooled correctly. Do not obstruct the rear
part of the amplifier (in order to guarantee the necessary air intake).
CONNECTION TO THE MAINS
The unit must be connected to a mains supply that can deliver at least the maximum power
required. Do not use extension cables or adapters that could compromise the proper current
delivery.
COOLING
Cooling is handled by a circuit that automatically regulates the dual speed of the fan in relation
to the temperature rise. The second speed is used when the temperature gets over 60°C/140°F
(to get the maximum fan noise reduction).
Cooling is forced, the air is taken in from the front and pushed out from the sides.
AUDIO INPUT / AMPLIFIED OUTPUT CONNECTIONS