RCA RACP1206 Скачать руководство пользователя страница 8

11

12

INSTALLATION  INSTRUCTIONS  (optional)

Installation in a sliding sash 

window

1. Cut the foam seal(adhesive type) to the proper 
    length and attach it to the window frame,Fig.14.

2. Attach the window slider kit to the window stool. 
   Adjust the length of the window slider kit according 
   to the width of  window, shorten the adjustable window 
   kit if the width of window is less than 26.5 inches. Open 
   the window sash and place the window slider kit on the 
   window stool. See Fig.15.

3. Cut the foam seal(adhesive type) to the proper 
    length and attach it on the top of the window. 
   Shown as in Fig.16.

4. Close the sliding sash securely against the window.

5. Cut the foam seal to an appropriate length and 
    seal the open gap between the top window sash 
    and outer window sash. Shown as in Fig.17.

Foam seal

Foam seal A
(adhesive type)

Window
panel

Fig.14

Fig.15

Fig.16

Fig.15

Window
panel

or

or

INSTALLATION  INSTRUCTIONS  (optional)

Exhaust hose installation:

     The exhaust hose and adaptor must be installed or removed
     in accordance with the usage mode. 

The duct can be compressed or extended moderately 
according to the installation requirement, but it is 
desirable to keep the duct length to a minimum.  

     1.  Install the window Exhaust adaptor B  onto the exhaust 
          hose as shown in Fig.18a. or Fig.18b. Refer to the previous 
          pages for window kit installation.
     2.  Place the Exhaust hose over against the air outlet opening
          hook(See Fig.19) and flat the other end(See Fig.20) for 
         quick installation.
     

IMPORTANT:

     DO NOT OVER BEND THE DUCT (SEE Fig.22)

Fig.18b

Fig.19

Fig.20

Fig.22

     

The exhaust hose can be installed into the wall

     

(Not applicable to the units without adaptor A, expansion

      plugs and wooden screws of Accessories )

.

     1. Prepare a hole in the wall. Install the wall Exhaust adaptor A 
         onto the wall(outside) by using 4 expansion plugs and 
         wooden screws, be sure to fix thoroughly. (See Fig.21)
      2. Attach the Exhaust hose to wall Exhaust adaptor A.
      

Fig.21

max 120CM

min  30CM

Adaptor A

Expansion plug 
position

Adaptor 
cap

     

Note: 

     

Cover the hole using the adaptor cap when not in use. 

Pu

sh i

n

Hook

Fig.18a

           COOL,HEAT(heat pump type) or  AUTO  
           mode

            FAN,DEHUMIDIIFY or HEAT(electrical heat type)  
            mode 

     Install

     Remove

CAUTION:

     Make sure that there is no obstacle around the air outlet of
     the exhaust hose (in the range of 500mm) in order to the 
     exhaust system works properly.

26.5 ~ 48.0

26.5 ~ 48.0

Содержание RACP1206

Страница 1: ...find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions carefully and save this manual for future use MOBILE TYPE AIR CONDITIONERS LOCAL AIR CONDITIONERS RACP1206 ...

Страница 2: ...upervision be applicable for the European Countries This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety be applicable for other countries except the European Countrie...

Страница 3: ...ABLE REMARK DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B...

Страница 4: ... Safety rules Suggested tools for window kit installation 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window kit needs to be cut down in size because the window is too narrow for direct installation MODE ROOM TEMPERATURE COOL DRY O O 17 C 62 F 35 O O C 95 F O O 13 C 55 F 35O O C 95 F HEAT heat pump type O O 5 C 41 F O O 30 C 88 F HEAT ...

Страница 5: ... in a range of 17 C 62 F to 30 C 88 F or the TIMER setting in a range of 0 24hrs 6 UP and DOWN button NOTE The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the butt...

Страница 6: ...p timed program When the malfunction E1 or E2 occurs the Auto Start Stop timed program will also be cancelled SLEEP operation The air conditioner will control room temperature automatically round the temperature point set by you Under AUTO mode you can not select the fan speed When the operation is ON press the SWING button can stop the louver at the desired angle The louver swing up O to an angle...

Страница 7: ... window applications However it may be necessary for you to improvise modify some aspects of the installation procedures for certain types of window Please refer to Fig 8 Fig 9 for minimum and maximum window openings Window slider kit can be fixed with a bolt see Fig 9a INSTALLATION INSTRUCTIONS optional Installation in a double hung sash window 1 Cut the foam seal adhesive type to the proper leng...

Страница 8: ... moderately according to the installation requirement but it is desirable to keep the duct length to a minimum 1 Install the window Exhaust adaptor B onto the exhaust hose as shown in Fig 18a or Fig 18b Refer to the previous pages for window kit installation 2 Place the Exhaust hose over against the air outlet opening hook See Fig 19 and flat the other end See Fig 20 for quick installation IMPORTA...

Страница 9: ... Grasp the upper filter tab Fig 26 pull the filter out then up Remove the lower filter by loosening the screw taking down the air inlet grille then removing the air filter as shown in Fig 27 28 Cleaning Wash the air filter by immersing it gently in warm water O O about 40 C 104 F with a neutral detergent Rinse the filter and dry it in a shady place Mounting Insert the upper air filter from upward ...

Страница 10: ...r is blocked by dust 2 Not cool enough Place the unit on a flat level ground if possible It is normal The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air conditioner 4 Noisy or vibration 5 Gurgling sound Switch on again after the unit has cool down The automatic over heat protection function When the temperature at the air outlet O O exceed...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: