RCA RACP1206 Скачать руководство пользователя страница 6

7

8

OPERATING  INSTRUCTIONS

Press the ION button, the ion generator 
is ener gized and will help to remove 
pollen and impur ities from the air, and
 trap them in the filter. Press it again to 
stop the function.

8

ION button(optional)

Operating Instructions

-    Press the  "MODE" button until the  "COOL" 
     indicator light comes on. 
-    Press the  ADJUST buttons "

" or "    " to 

     select your desired room temperature. The
     temperature can be set within a range of 

O

O

O

O

     17 C-30 C/62 F-88 F.  
-    Press the "FAN SPEED" button to choose the 
     fan speed. 

 

-    Press the  "MODE" button until the  "DRY" indicator 
     light comes on.     
-    Under this mode, you cannot select a fan speed or 
     adjust the temperature. The fan motor operates at 
     LOW speed.
-    Keep windows and doors closed for the best 
     dehumidifying effect.
-    Do not put the duct to window.
     
     

COOL operation

DRY  operation

-    Press the  "MODE" button until the
    "FAN " indicator  light comes on. 
-    Press the "FAN SPEED" button to 
     choose the fan speed. The temperature
     cannot be adjusted.
-    Do not put the duct to window.

FAN operation

TIMER operation

-    Press the  "MODE" button until the  "HEAT" 
     indicator light comes on. 
-    Press the  ADJUST buttons "

" or "    " to 

     select your desired room temperature. The
     temperature can be set within a range of 

O

O

O

O

     17 C-30 C/62 F-88 F.  
-    Press the "FAN SPEED" button to choose the 
     fan speed. For some models, the fan speed 
     can not be adjusted under HEAT mode.

 

HEAT  operation

(cooling only models without)

AUTO  operation

-    When you set the air conditioner in AUTO 
     mode, it will automatically select cooling, 
     heating(cooling only models without), or fan 
    only operation depending on what temperature 
     you have selected and the room temperature.

-    When the unit is on, first  press the 
      Timer button, the TIMER OFF 
      indicator light illuminates. It indi-
      cates the Auto Stop program is 
      initiated. 
 -    When the unit is off, first  press the 
      Timer button, the TIMER ON indic-
      ator light illuminates. It indicates 
      the Auto Start program is initiated. 
 -    Press or hold the UP or DOWN 
      button to change the Auto time by 
      0.5 hour increments, up to 10 hours, 
      then at 1 hour increments up to 24
      hours. The control  will count down 
      the time remaining until start. 
 -    The selected time will register in 5 
      second and the system will autom-
      atically revert back to display the 
      previous temperature setting.
 -   Turning the unit ON or OFF at any 
      time or adjusting the timer setting 
      to 0.0 will cancel the Auto Start/
      Stop timed program.
 -    When the malfunction (E1 or E2)
      occurs, the Auto Start/Stop timed
      program will also be cancelled.

SLEEP operation

-    The air conditioner will control room 
      temperature automatically round the 
      temperature point set by you.
-    Under AUTO mode, you can not 
     select the fan speed.

When the operation is ON, press the 
SWING button can stop the louver at
the desired angle. The louver swing up

O

to an angle of 6  for each press. Keep 
pressing the button more than 2 seconds 
can initiate the auto swing feature.

9

SWING button

(Applicable to the models with auto swing feature only)

Press this button, the selected temperature 
will increase(cooling) or decrease(heating) 

O

O

by 1

C/2 F 30 minutes.The temperature 

will then increase(cooling) or decrease

O

O

(heating) by another 1

C/2 F after an 

additional 30 minutes. This new temper-
ature will be maintained for 7 hours 
before it returns to the originally selected 
temperature. This ends the Sleep mode 
and the unit will continue to operate as 
originally programmed. 

NOTE: 

This feature is unavailabe under 

FAN or DRY mode.

OPERATING  INSTRUCTIONS

Other features

After the unit has stopped, it can not be restarted
operation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes. 

Wait 3 minutes before resuming operation

The louver can be adjusted manually or 
automatically according to the different models.

   

Adjust the air flow direction manually

  (Fig.5):

   The louver can be set to the desired position
    manually. The max setting angle is about

O

    60 , please do not force to set any larger. 
    Do not place any heavy objects or other loads
    on the louver, doing so will cause damage to
    the unit.
    

Ensure the louver is fully opened under 

    heating operation.
    Keep the louver fully opened during 
    operation.

    

Adjust the air flow direction automatically

    (Fig.6):

    When operation is ON, the louver opens fully.
    Use the SWING button on the remote 
    controller can stop the louver at the desired
    angle.

O

    The louver move up to an angle of 6  for 
    each press until it move to a position which
    would affect the cooling or heating effect 
    of the air conditioner, it would automatically 
    change the swing direction.
    If keep pressing the SWING button more 
    than 2 seconds, the auto swing feature is 
    activated. The louver swings as shown in 
    Fig.6
     

Air flow direction adjustment

Fig.5

Adjust manually

Swing automatically

Fig.6

If the unit breaks off unexpectedly due to the 
power cut,it will restart with the previous 
function setting automatically when the power 
resumes.

Auto-Restart(on some models)

Содержание RACP1206

Страница 1: ...find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions carefully and save this manual for future use MOBILE TYPE AIR CONDITIONERS LOCAL AIR CONDITIONERS RACP1206 ...

Страница 2: ...upervision be applicable for the European Countries This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety be applicable for other countries except the European Countrie...

Страница 3: ...ABLE REMARK DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B...

Страница 4: ... Safety rules Suggested tools for window kit installation 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window kit needs to be cut down in size because the window is too narrow for direct installation MODE ROOM TEMPERATURE COOL DRY O O 17 C 62 F 35 O O C 95 F O O 13 C 55 F 35O O C 95 F HEAT heat pump type O O 5 C 41 F O O 30 C 88 F HEAT ...

Страница 5: ... in a range of 17 C 62 F to 30 C 88 F or the TIMER setting in a range of 0 24hrs 6 UP and DOWN button NOTE The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the butt...

Страница 6: ...p timed program When the malfunction E1 or E2 occurs the Auto Start Stop timed program will also be cancelled SLEEP operation The air conditioner will control room temperature automatically round the temperature point set by you Under AUTO mode you can not select the fan speed When the operation is ON press the SWING button can stop the louver at the desired angle The louver swing up O to an angle...

Страница 7: ... window applications However it may be necessary for you to improvise modify some aspects of the installation procedures for certain types of window Please refer to Fig 8 Fig 9 for minimum and maximum window openings Window slider kit can be fixed with a bolt see Fig 9a INSTALLATION INSTRUCTIONS optional Installation in a double hung sash window 1 Cut the foam seal adhesive type to the proper leng...

Страница 8: ... moderately according to the installation requirement but it is desirable to keep the duct length to a minimum 1 Install the window Exhaust adaptor B onto the exhaust hose as shown in Fig 18a or Fig 18b Refer to the previous pages for window kit installation 2 Place the Exhaust hose over against the air outlet opening hook See Fig 19 and flat the other end See Fig 20 for quick installation IMPORTA...

Страница 9: ... Grasp the upper filter tab Fig 26 pull the filter out then up Remove the lower filter by loosening the screw taking down the air inlet grille then removing the air filter as shown in Fig 27 28 Cleaning Wash the air filter by immersing it gently in warm water O O about 40 C 104 F with a neutral detergent Rinse the filter and dry it in a shady place Mounting Insert the upper air filter from upward ...

Страница 10: ...r is blocked by dust 2 Not cool enough Place the unit on a flat level ground if possible It is normal The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air conditioner 4 Noisy or vibration 5 Gurgling sound Switch on again after the unit has cool down The automatic over heat protection function When the temperature at the air outlet O O exceed...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: