RCA RACP1206 Скачать руководство пользователя страница 4

3

4

To prevent injury to the user or other people and property damage, the following  instructions must be
followed. Incorrect operation due to ignoring of instructions may cause harm or damage. 

   Your air conditioner should be used in such a way 
    that it is protected from moisture. e.g. condensation, 
   splashed water, etc. Do not place or store your air 
   conditioner where it can fall or be pulled into water 
   or any other liquid. Unplug immediately.
   Always transport your air conditioner in a vertical 
   position and stand on a stable, level surface during 
   use. 
   Turn off the product when not in use.
   Always contact a qualified person to carry out 
   repairs. If the supply cord is damaged it must be 
   repaired by a qualified repairer.
   Keep an air path of at least 30cm all around the 
   unit  from walls, furniture and curtains.
   If the air conditioner is knocked over during use, 
   turn off the unit and unplug from the mains supply
   immediately.

   
    
   

SAFETY  PRECAUTIONS

!

Always do this

   Do not operate your air conditioner in a wet room
   such as a bathroom or laundry room.
   Do not touch the unit with wet or damp hands or 
   when barefoot.
   Do not press the buttons on the control panel with
   anything other than your fingers.
   Do not remove any fixed covers. Never use this 
   appliance if it is not working properly, or if it has
   been dropped or damaged.
   Never use the plug to start and stop the unit. 
   Always use the switch on the control panel.
   Do not cover or obsturct the inlet or outlet grilles.
   Do not use hazardous chemicals to clean or come
   into contact with the unit. Do not use the unit in the
   presence of inflammable substances or vapour such
   as alcohol, insecticides, petrol,etc.
   Do not allow children to operate the unit 
   unsupervised.
   Do not use this product for functions other than
   those described in this instruction manual.

Never do this

Energy Save

Use the unit  in the recommended room size.
Locate the unit where furniture cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part of the day.
Keep the filters clean.
Keep doors and windows closed to keep cool air in and warm air out.

The air conditioner must be operated within the  temperature range indicated below:

Operating condition

Safety r ules

Suggested tools for window kit installation

1. Screwdriver(medium size Phillips)            
2. Tape measure or ruler 
3. Knife or scissors
4. Saw(In the event that the window kit needs to be cut down in size because 
     the window is too narrow for direct installation)

MODE

ROOM TEMPERATURE

COOL

DRY

O

O

17 C(62 F)~35

O

O

C(95 F)

O

O

13 C(55 F)~35

O

O

C(95 F)

HEAT(heat pump type)

O

O

5 C(41 F)~

O

O

30 C(88 F)

HEAT(electrical heat type)

O

O

<30 C/88 F

Be sure the electrical service is adequate for the model you have chosen. This information can be found 
on the serial plate, which is  located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is 
important. The power cord is equipped with a three-prong grounding plug for protection against shock 
hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend
to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified 
electrician install the proper receptacle. 
Ensure the receptacle is accessible after the unit installation.

WARNING

For your safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance.
Avoid fire hazard or electric shock. Do not use an  extension cord or an adaptor plug. Do not remove 
any prong from the power cord.

WARNING

Electrical Infor mation

IDENTIFICATION  OF  PARTS

Note: Performance may be reduced outside of these operating temperatures.

Check all the accessories are included in the package and please refer to the installation instructions for 
their usage.

NOTE: Optional parts(     ), some models without.

All the illustrations in this manual are for explanation  purpose only. Your air conditioner 
may be slightly different. The actual shape shall prevail.

NOTE:

Accessories

PARTS :

PARTS NAME :

Wall Exhaust Adaptor A(  )

Expansion Plug and wooden  screw()

QUANTITY :

1 set

1 set

1 pc

4/ pc

 Foam seal

3/pc

TEMP

AUTO 

COOL

DRY

HEA

T

FAN

HIGH

MED

LOW

MODE

FAN SPEED

SWING

TIMER ON

ECONOMY

ON/OFF

TIMER OFF

RESET LOCK

SET TEMPERA

TURE(   C)

        FOLLOW

             ME

        LED

    DISPLA

Y

ION

TURBO

 Remote Controller and Battery
(For remote control models only)

1set

 Drain hose 

         Adaptor B(round mouth)  ()

1pc

()

or

Exhaust hose(supplied),adapter B(round 

mouth or flat month:depending on models) 

and Window Slider Kit and bolt

()

Содержание RACP1206

Страница 1: ...find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner Before operating this product please read the instructions carefully and save this manual for future use MOBILE TYPE AIR CONDITIONERS LOCAL AIR CONDITIONERS RACP1206 ...

Страница 2: ...upervision be applicable for the European Countries This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety be applicable for other countries except the European Countrie...

Страница 3: ...ABLE REMARK DISPOSAL Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessary It is prohibited to dispose of this appliance in domestic household waste For disposal there are several possibilities A The municipality has established collection systems where electronic waste can be disposed of at least free of charge to the user B...

Страница 4: ... Safety rules Suggested tools for window kit installation 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window kit needs to be cut down in size because the window is too narrow for direct installation MODE ROOM TEMPERATURE COOL DRY O O 17 C 62 F 35 O O C 95 F O O 13 C 55 F 35O O C 95 F HEAT heat pump type O O 5 C 41 F O O 30 C 88 F HEAT ...

Страница 5: ... in a range of 17 C 62 F to 30 C 88 F or the TIMER setting in a range of 0 24hrs 6 UP and DOWN button NOTE The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Up and Down buttons at the same time for 3 seconds 3 Used to initiate the AUTO ON start time and AUTO OFF stop time program in conjuction with the butt...

Страница 6: ...p timed program When the malfunction E1 or E2 occurs the Auto Start Stop timed program will also be cancelled SLEEP operation The air conditioner will control room temperature automatically round the temperature point set by you Under AUTO mode you can not select the fan speed When the operation is ON press the SWING button can stop the louver at the desired angle The louver swing up O to an angle...

Страница 7: ... window applications However it may be necessary for you to improvise modify some aspects of the installation procedures for certain types of window Please refer to Fig 8 Fig 9 for minimum and maximum window openings Window slider kit can be fixed with a bolt see Fig 9a INSTALLATION INSTRUCTIONS optional Installation in a double hung sash window 1 Cut the foam seal adhesive type to the proper leng...

Страница 8: ... moderately according to the installation requirement but it is desirable to keep the duct length to a minimum 1 Install the window Exhaust adaptor B onto the exhaust hose as shown in Fig 18a or Fig 18b Refer to the previous pages for window kit installation 2 Place the Exhaust hose over against the air outlet opening hook See Fig 19 and flat the other end See Fig 20 for quick installation IMPORTA...

Страница 9: ... Grasp the upper filter tab Fig 26 pull the filter out then up Remove the lower filter by loosening the screw taking down the air inlet grille then removing the air filter as shown in Fig 27 28 Cleaning Wash the air filter by immersing it gently in warm water O O about 40 C 104 F with a neutral detergent Rinse the filter and dry it in a shady place Mounting Insert the upper air filter from upward ...

Страница 10: ...r is blocked by dust 2 Not cool enough Place the unit on a flat level ground if possible It is normal The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air conditioner 4 Noisy or vibration 5 Gurgling sound Switch on again after the unit has cool down The automatic over heat protection function When the temperature at the air outlet O O exceed...

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: