Contents of Accessory Kit

2 Lens Masks

Indoor Switchplate Label

3 Wire Nuts

Crossbar

with Green Ground Screw

Hanging Hook

1/2" Close Up Plugs (3)

Slotted Screws (4)

Finishing Cap

O-ring Gasket

Center Mounting Screw

Foam Gaskets (2)

Metal Plate

13

STL200

How Does the STEALTH Work?

Stealth’s infrared sensor “sees”

small temperature changes caused

by the motion of people or cars

within its protection zone and turns

on lights automatically. It welcomes

visitors and may deter intruders.

How long do the lights stay on?

Lights remain on as long as there is

movement within the protection

zone. Once the zone is vacated

lights can be adjusted to remain on

approximately 5 seconds up to 12

minutes. Since the lights are on

only when needed, and the sensor

uses only one watt the Stealth is

extremely energy efficient.

Can outdoor lights still be turned

on with the light switch?

Yes. Stealth can be controlled by a

conventional indoor switch or circuit

breaker. Lights can be turned on or

off manually at night only.

Manual Override Mode:

(to keep lights on) Flip the switch

twice slowly (off-on-off-on) within

2–3 seconds.

To Resume Automatic Mode:

Flip the switch once (off-on) within

2 seconds. Sensor will reset to

Automatic Mode.

Will Stealth detect animals?

Stealth may detect large animals.

Having animals trigger the sensor

can give property a “lived-in” look.

However, you can limit animal

detection by turning down the

How are the Time, Sensitivity and

Photocell adjusted?

Time: Sets the time that lights

will remain on after the detection

zone is vacated from approximately

5 seconds to 12 minutes.

Factory Setting: 5–8 minutes

Sensitivity: Increases or

decreases the responsiveness

and range of the sensor

(Adjusts from 30% to 100%)

Factory Setting: 100%

Photocell: Located behind the

lens. For night only operation, turn

the knob all the way clockwise to

(to the moon symbol). For 24 hour

operation turn the knob all the way

counterclockwise (sun & moon).

Adjust clockwise to have the sensor

come on later at dusk, counter-

clockwise to have it come on earlier.

Factory Setting: Night Only

Control Panel:

2

Masking the Lens 

sensitivity knob and/or by using

the plastic lens mask supplied

on the lower part of the lens.

Содержание STL200

Страница 1: ...protection I E C specs UL Listing Raintight Photoelectric Switch STL200 Installation Manual STEALTH Toll free fax e mail Send a fax to 888 722 1232 Tech Help Line Call our experts 888 722 1000 Visit...

Страница 2: ...ns Do not install sensors on a circuit that feeds motor loads like kitchen appliances HVAC equipment washer dryer or garage door openers Sensor must be below and as far as possible away from lights Se...

Страница 3: ...night only Manual Override Mode to keep lights on Flip the switch twice slowly off on off on within 2 3 seconds To Resume Automatic Mode Flip the switch once off on within 2 seconds Sensor will reset...

Страница 4: ...ich time the controlled lights will go on At night the LED serves as a deterrent indicating a security device in operation Choosing a Location LED Detection Indicator 100 Top View 30 Side View 30 10 3...

Страница 5: ...round Power In White White Red pigtail is only used to switch remote or additional fixtures 4 EZ Plate 1 Lights may turn on occasionally during rain snow and windstorms because the sensor is detecting...

Страница 6: ...reference STL200 Power In Sensor Red Black White Ground 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zone may be high...

Страница 7: ...l help is needed Control Panel 6 Start Finish 1 Check that lamps and fixtures work Compare wiring to the wiring diagram in this manual Check that the power is on 2 If installing during daylight rememb...

Страница 8: ...Make sure heat from lights is not triggering sensor Make sure the sensor is below and as far as possible away from lights Technical Tips Lights Do Not Turn Off 7 WRONG OK OK WRONG 20 Safety Zone OK W...

Страница 9: ...s are protected under Canadian U S and international intellectual property laws 2010 RC Lighting Caract ristiques Capacit de commutation 8 A Tension 120 volts Incandescence de 1 000 watts Fluorescence...

Страница 10: ...ontinuer Tout le c blage doit tre conforme aux codes locaux de l lectricit et doit tre effectu par un lectricien comp tent La charge d clairage totale raccord e au Stealth ne doit pas d passer 8 A inc...

Страница 11: ...5 secondes et 12 minutes R glage de l usine 5 8 minutes Sensibilit Accro t ou r duit la r action et la port e du d tecteur r glage de 30 100 R glage de l usine 100 Photocellule Derri re la lentille P...

Страница 12: ...or repaired at our option if it proves to be defective in workmanship or materials within ten years from the date of original purchase For repair replacement return the product freight prepaid and ins...

Страница 13: ...the lens with opaque weatherproof tape to create an Animal Alley 4 Although it is surge and transient protected the sensor may turn on occasionally during extreme voltage surges 5 A possible source of...

Страница 14: ...quickly To fix move the sensor 4 Check that movement far away and directly towards sensor is not entirely within one zone Sensor will not detect until movement crosses zones Micro Adjust sensor by mov...

Страница 15: ...tings will adjust operation during dusk and dawn 8 Your sensor is ready for operation See the Technical Tips pages 7 11 if additional help is needed 1 Check that lamps and fixtures work Compare wiring...

Страница 16: ...sor away from reflective objects or move the objects and lower sensitivity 9 Self ballasted PL lamps may cause cycling on off 10 Check Solutions 2 4 5 6 and 7 under If Lights Do Not Turn Off 20 Safety...

Отзывы: