Noisy Operation

Check to make sure the fan blade is rotating freely.

Make sure the water cooler is correctly mounted to the wall. Absence of the two lower 
mounting bolts may cause excess noise and vibration.
Check the compressor mounting to make sure the pins and clips are not rattling. If the 
compressor appears to be noisy internally, it must be replaced.

Restricted Or No Water Flow

Ensure water supply service stop valve is fully open.

Verify minimum 200 kPa supply line flow pressure.

Check for twists or kinks in bubbler tubing.

Check the water inlet strainer. Sediment from the main supply can get trapped in the 
screen along with installation materials such as pipe dope and flux. The screen should 
be cleaned and checked on a regular basis and replaced if needed.
The cartridge valve located in the water control assembly or bubbler can also become 
clogged with foreign material. The cartridge valve can only be replaced and not 
repaired.
The water cooler may also develop a freezing condition in which the water will become 
frozen inside the evaporator coil. This indicates a refrigeration problem or thermostat 
failure in which case the water cooler needs to be checked by a qualified technician

Compressor Cycling on 
Overload Protector

A dirty condenser or a blocked fan will cause a high head pressure and frequent 
cycling of the overload protector.
Check the incoming voltage to make sure it is within 10% of the serial nameplate 
rating.
A restriction or moisture in the system will also cause intermittent cycling. A certified 
refrigeration mechanic should be contacted in this situation.
Change the overload or relay if defective.

Cleaning & Maintenance 

1.  Motors have lifetime lubrication and do not require scheduled maintenance.
2.  Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor off and it will cycle 

on and off with no cold water coming out of bubbler. Periodically clean with vacuum cleaner, air hose or brush the 
condenser fins and cabinet ventilation louvers. In environments where dirt and dust is more prevalent, clean more 
frequently.

3.  Periodically remove access panels and clean out in-line strainer.
4.  Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void RBA warranty.
5.  Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra care must be used cleaning 

chrome plated items and mirror finished stainless steel. They can scratch easily and should only be cleaned using a 
clean, soft cloth and mild soap with water or a mild glass cleaner

Cartridge Spare Parts

RBA Code No.

Description

RBA7000-065-001

Valve Cartridge Assembly

Note:

 This product should be installed, by suitably qualified persons, in a fit for purpose application, to suitable materials, 

using suitable fixings and comply with any relevant codes. It should be inspected periodically for signs of wear and tear that 
may affect performance or safety.

Dimensions are subject to manufacturer’s tolerance of +/-10mm. Rough-in should be completed with each fixture. 

Important:

 Installation Instructions are subject to change without notice. Please visit 

our websites

 for latest revision.

Содержание RBA2770 Series

Страница 1: ...A2777 Series Stainless Series MODEL WALL MOUNTED COMPACT WATER COOLERS As improvements in the design and performance of RBA products are continuous specifications may be subject to change without notice The illustrations and descriptions herein are applicable to production as of the date of this Installation Instructions Sheet Revised 08 22 2022 by RBA Group II rba2770 series rba2777 series 0822 R...

Страница 2: ...cessive condensation Hydraulic Requirements Operating pressure 200 500kPa Inlet G1 2B Outlet 40mm BSP Waste Water Temp 4o 32o Provide 102mm minimum clear space on fixture sides to allow for proper ventilation through cabinet louvers Rough in and Dimensions Prior to roughing in consult with local state and federal codes for proper mounting height Installation to be done in accordance with AS NZS 35...

Страница 3: ...ff Problem Probable cause Compressor Does Not Run Check the electrical receptacle for power and correct voltage The incoming voltage must be within 10 of the rated voltage on the serial nameplate The cold thermostat is accessible by removing the bottom access cover If the cold thermostat capillary bulb loses its charge or becomes kinked it will fail in the open position causing a disruption of pow...

Страница 4: ...e sure it is within 10 of the serial nameplate rating A restriction or moisture in the system will also cause intermittent cycling A certified refrigeration mechanic should be contacted in this situation Change the overload or relay if defective Cleaning Maintenance 1 Motors have lifetime lubrication and do not require scheduled maintenance 2 Excess dirt or poor ventilation will cause the compress...

Отзывы: