INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SYDNEY  |  MELBOURNE  |  BRISBANE  |  PERTH  |  AUCKLAND

Australia

   1300 788 778   www.rba.com.au   |

   New Zealand

   0800 722 111  www.rbagroup.co.nz

2 of 4

Components Supplied by Others

•  Wall fasteners for signage mounting 
•  Pipe sealant or Teflon tape for sealing water connections 
•  40mm trap [Due to cold waste water, we recommend the trap supplied by installer be insulated to prevent excessive 

condensation]

Hydraulic Requirements 

Operating pressure: 

200-500kPa

Inlet: 

 

  G1/2B

Outlet:   

 

40mm BSP Waste 

Water Temp: 

 

4o - 32o

Provide 102mm minimum clear space on fixture sides to allow for proper ventilation through cabinet louvers.

Rough-in and Dimensions

Prior to roughing-in consult with local, state, and federal codes for proper mounting height. Installation to be done in 
accordance with AS/NZS 3500.1 and AS/NZS 3500.2

Air Flow

464

63

51

851

317

98

153

306

25

730

CL

1016

Rim

Height

1045

Orifice

Height

CL

Supply 15mm BSP

Trap (not furnished)

Waste location

FRONT VIEW

SIDE VIEW

Finished Floor

Electric

Outlet

Содержание RBA2770 Series

Страница 1: ...A2777 Series Stainless Series MODEL WALL MOUNTED COMPACT WATER COOLERS As improvements in the design and performance of RBA products are continuous specifications may be subject to change without notice The illustrations and descriptions herein are applicable to production as of the date of this Installation Instructions Sheet Revised 08 22 2022 by RBA Group II rba2770 series rba2777 series 0822 R...

Страница 2: ...cessive condensation Hydraulic Requirements Operating pressure 200 500kPa Inlet G1 2B Outlet 40mm BSP Waste Water Temp 4o 32o Provide 102mm minimum clear space on fixture sides to allow for proper ventilation through cabinet louvers Rough in and Dimensions Prior to roughing in consult with local state and federal codes for proper mounting height Installation to be done in accordance with AS NZS 35...

Страница 3: ...ff Problem Probable cause Compressor Does Not Run Check the electrical receptacle for power and correct voltage The incoming voltage must be within 10 of the rated voltage on the serial nameplate The cold thermostat is accessible by removing the bottom access cover If the cold thermostat capillary bulb loses its charge or becomes kinked it will fail in the open position causing a disruption of pow...

Страница 4: ...e sure it is within 10 of the serial nameplate rating A restriction or moisture in the system will also cause intermittent cycling A certified refrigeration mechanic should be contacted in this situation Change the overload or relay if defective Cleaning Maintenance 1 Motors have lifetime lubrication and do not require scheduled maintenance 2 Excess dirt or poor ventilation will cause the compress...

Отзывы: