INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
SYDNEY | MELBOURNE | BRISBANE | PERTH | AUCKLAND
Australia
1300 788 778 www.rba.com.au |
New Zealand
0800 722 111 www.rbagroup.co.nz
2 of 4
Components Supplied by Others
• Wall fasteners for signage mounting
• Pipe sealant or Teflon tape for sealing water connections
• 40mm trap [Due to cold waste water, we recommend the trap supplied by installer be insulated to prevent excessive
condensation]
Hydraulic Requirements
Operating pressure:
200-500kPa
Inlet:
G1/2B
Outlet:
40mm BSP Waste
Water Temp:
4o - 32o
Provide 102mm minimum clear space on fixture sides to allow for proper ventilation through cabinet louvers.
Rough-in and Dimensions
Prior to roughing-in consult with local, state, and federal codes for proper mounting height. Installation to be done in
accordance with AS/NZS 3500.1 and AS/NZS 3500.2
Air Flow
464
63
51
851
317
98
153
306
25
730
CL
1016
Rim
Height
1045
Orifice
Height
CL
Supply 15mm BSP
Trap (not furnished)
Waste location
FRONT VIEW
SIDE VIEW
Finished Floor
Electric
Outlet