8
PROBLEM
PROBABLE CAUSE
SOLUTION
Water flows continuously
(does not stop)
Object in front or within
sensor’s range
Remove the object
Sensor, cables or power
supply unit damaged
Contact product
distributor
Power supply connected
directly to solenoid valve
Disconnect power supply
wiring under basin and
connect power supply to
sensor plug. Ensure to
also connect sensor to
solenoid plug.
Dirt in diaphragm
Turn water and power
off. Clean and replace
diaphragm. Turn water
and power on.
Water Flows (intermittent
failures or incorrect
function)
Highly reflective surface
Unit not recommended
for use with high polished
stainless steel basins
(satin finish OK). Place
dull coloured strip
opposite sensor.
Hands too low or high in
basin & not directly in
front of sensor when in
use
Users to place hands in
flow stream directly in
front of sensor to correctly
activate
ii/rba1211-600/0618