7
Trouble Shooting
PROBLEM
PROBABLE CAUSE
SOLUTION
Water droplets appearing
under basin
Gasket improperly
installed
Install or realign gasket
Temperature indicator not
installed
Insert appropriate
temperature indicator
Damaged ‘Formatta’ Valve
Body O-ring
Replace O-ring
Water does not flow and
solenoid valve does
produce an audible CLICK
Water turned off
Turn water on
Inlet valve closed or
clogged
Open valve or remove
and clean strainer (refer
RBA1074-999-001
detail)
Aerator clogged
Remove and clean aerator
Braided hose kinked
Replace braided hose
Solenoid valve incorrectly
installed
Check flow direction on
valve’s body. Reassemble
if necessary
Water does not flow and
solenoid valve does not
produce an audible CLICK
No power connected
Check power supply &
breaker
Power supply unit
disconnected
Check it and plug it in
Sensor, cables or power
supply unit damaged
Check electrical plug pins
are OK. Where damage
has occurred contact
product distributor
Direct/bright light
Remove direct/bright light
Sensor light
registers but no flow
Direct/bright light
Remove direct/bright light
Continued...